Search Results - "Chason, M"
-
1
Normal Ribosomal Biogenesis but Shortened Protein Synthetic Response to Acute Eccentric Resistance Exercise in Old Skeletal Muscle
Published in Frontiers in physiology (14-01-2019)“…Anabolic resistance to feeding in aged muscle is well-characterized; however, whether old skeletal muscle is intrinsically resistant to acute mechanical…”
Get full text
Journal Article -
2
Immune Thrombocytopenia (ITP) in a Pediatric Patient Positive for SARS-CoV-2
Published in Pediatrics (Evanston) (01-08-2020)“…Immune thrombocytopenia (ITP) is a potential presentation of COVID-19. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral testing should be…”
Get full text
Journal Article -
3
Acute resistance exercise activates rapamycin‐sensitive and ‐insensitive mechanisms that control translational activity and capacity in skeletal muscle
Published in The Journal of physiology (15-01-2016)“…Key points Ribosome biogenesis is the primary determinant of translational capacity, but its regulation in skeletal muscle following acute resistance exercise…”
Get full text
Journal Article -
4
Printed Organic Semiconducting Devices
Published in Proceedings of the IEEE (01-07-2005)“…Recent improvements in carrier mobility, environmental stability, and advancements in p- and n-type organic semiconductor materials have resulted in reports of…”
Get full text
Journal Article -
5
-
6
[ital In] [ital situ] x-ray reflectivity measurements of thin film structural evolution
Published in Journal of vacuum science & technology. A, Vacuum, surfaces, and films (01-07-1994)“…X-ray reflectivity using energy dispersive x-ray detection has been used to investigate the characteristics of vacuum-deposited thin films. A resolution of 0.3…”
Get full text
Journal Article -
7
In situ x-ray reflectivity measurements of thin film structural evolution
Published in Journal of vacuum science & technology. A, Vacuum, surfaces, and films (15-11-1993)“…X-ray reflectivity using energy dispersive x-ray detection has been used to investigate the characteristics of vacuum-deposited thin films. A resolution of 0.3…”
Get full text
Journal Article -
8
In situ x‐ray reflectivity measurements of thin film structural evolution
Published in Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films (01-07-1994)“…X‐ray reflectivity using energy dispersive x‐ray detection has been used to investigate the characteristics of vacuum‐deposited thin films. A resolution of 0.3…”
Get full text
Conference Proceeding Journal Article -
9
Gold removal from component terminations via solder dipping
Published in Proceedings., 39th Electronic Components Conference (1989)“…Conversion of gold plating into tin/lead coating on interconnecting pads via solder dipping, i.e., the pretinning process, is investigated with X-ray…”
Get full text
Conference Proceeding -
10
Kinetic interactions of copper, lead and tin on solder coated PC boards studied using X-ray diffraction
Published in Proceedings. Seventh IEEE/CHMT International Electronic Manufacturing Technology Symposium (1989)“…X-ray diffraction has been used to monitor the growth and decay of the constituent phases existing in solder (60% Sn-40% Pb) coated Cu printed circuit boards…”
Get full text
Conference Proceeding -
11
X-ray diffraction study of copper-time intermetallic compounds on solder-coated PC boards
Published in Fifth IEEE/CHMT International Electronic Manufacturing Technology Symposium, 1988, 'Design-to-Manufacturing Transfer Cycle (1988)“…X-ray diffraction has been used in conjunction with standard metallography to study the formation and growth of copper-tin intermetallic compounds and their…”
Get full text
Conference Proceeding -
12
Practice Quality Improvement During Residency
Published in Academic radiology (01-07-2014)“…Rationale and Objectives Completing a systems-based practice project, equivalent to a practice quality improvement project (PQI), is a residency requirement by…”
Get full text
Journal Article -
13
Computed Tomography in the Diagnosis of Occult Open-Globe Injuries
Published in Ophthalmology (Rochester, Minn.) (01-08-2007)“…Purpose To determine the radiographic signs present on computed tomography (CT) most suggestive of occult open-globe injury. Design Retrospective chart review…”
Get full text
Journal Article -
14
Ion implantation of58Co for positron-annihilation Doppler-broadening measurements
Published in Applied Physics (01-01-1981)Get full text
Journal Article -
15
Evaluation of Fluoroscopic Cases Qualifying as Potential Fluoroscopic Sentinel Events
Published in Academic radiology (01-04-2013)“…Rationale and Objectives To address the risk of radiation injury during interventional procedures, the Joint Commission has defined prolonged fluoroscopy…”
Get full text
Journal Article -
16
Understanding and Using Fluoroscopic Dose Display Information
Published in Current problems in diagnostic radiology (01-01-2015)“…Fluoroscopically guided procedures are an area of radiology in which radiation exposure to the patient is highly operator dependent. Modern fluoroscopy…”
Get full text
Journal Article -
17
Myelography: A Primer
Published in Current problems in diagnostic radiology (01-07-2011)“…Despite recent trends toward evaluation of back and neck pain with magnetic resonance imaging, myelography and postmyelography computed tomography continue to…”
Get full text
Journal Article -
18
How Will You Need Me, How Will You Read Me, When I'm 64 (or More!)?: Volume Computed Tomographic Scanning and Information Overload in the Emergency Department
Published in Current problems in diagnostic radiology (01-09-2010)“…Computed tomographic (CT) scanning technology now employs up to 320 detector rows of 0.5-mm width and allows rapid acquisition of isotropic volume datasets…”
Get full text
Journal Article