Search Results - "Chaptinel, Jérôme"
-
1
Compressed Sensing Single–Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass
Published in JACC. Cardiovascular imaging (01-09-2014)“…Abstract Objectives The purpose of this study was to compare a novel compressed sensing (CS)–based single–breath-hold multislice magnetic resonance cine…”
Get full text
Journal Article -
2
Free-running 4D whole-heart self-navigated golden angle MRI: Initial results
Published in Magnetic resonance in medicine (01-11-2015)“…Purpose To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four‐dimensional (4D)…”
Get full text
Journal Article -
3
Respiratory self-navigated postcontrast whole-heart coronary MR angiography: initial experience in patients
Published in Radiology (01-02-2014)“…To assess the diagnostic performance of respiratory self-navigation for whole-heart coronary magnetic resonance (MR) angiography in a patient cohort referred…”
Get full text
Journal Article -
4
Greater than the sum: Federated analyses in Alzheimer’s disease using the Human Brain Project Medical Informatics Platform (MIP): Neuroimaging / New imaging methods
Published in Alzheimer's & dementia (01-12-2020)“…Abstract Background The abundance of patient data collected during clinical routine is rarely harnessed towards progress in neuroscience. However, multimodal…”
Get full text
Journal Article -
5
Greater than the sum: Federated analyses in Alzheimer’s disease using the Human Brain Project Medical Informatics Platform (MIP)
Published in Alzheimer's & dementia (01-12-2020)“…Background The abundance of patient data collected during clinical routine is rarely harnessed towards progress in neuroscience. However, multimodal real‐life…”
Get full text
Journal Article -
6
-
7
Comparison of three diffusion encoding schemes for cardiac imaging under free breathing conditions
Published in Journal of cardiovascular magnetic resonance (27-01-2016)Get full text
Journal Article -
8
-
9
Breath-held high-resolution cardiac T2 mapping with SKRATCH
Published in Journal of cardiovascular magnetic resonance (27-01-2016)Get full text
Journal Article -
10
Accelerated and KWIC-filtered cardiac T2 mapping for improved precision: proof of principle
Published in Journal of cardiovascular magnetic resonance (03-02-2015)Get full text
Journal Article -
11
A double echo ultra short echo time (UTE) acquisition for respiratory motion‐suppressed high resolution imaging of the lung
Published in Magnetic resonance in medicine (01-04-2018)“…Purpose Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal‐to‐noise ratio,…”
Get full text
Journal Article -
12
Fetal cardiac cine magnetic resonance imaging in utero
Published in Scientific reports (14-11-2017)“…Fast magnetic resonance imaging (MRI) led to the emergence of ‘cine MRI’ techniques, which enable the visualization of the beating heart and the assessment of…”
Get full text
Journal Article -
13
Accelerated and high-resolution cardiac T 2 mapping through peripheral k-space sharing
Published in Magnetic resonance in medicine (01-01-2019)“…To develop high-spatial-resolution cardiac T mapping that allows for a reduced acquisition time while maintaining its precision. We implemented and optimized a…”
Get full text
Journal Article -
14
Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach
Published in International Journal of Cardiovascular Imaging (01-12-2016)“…The border zone of post-infarction myocardial scar as identified by late gadolinium enhancement (LGE) has been identified as a substrate for arrhythmias and…”
Get full text
Journal Article -
15
Accelerated and high‐resolution cardiac T2 mapping through peripheral k‐space sharing
Published in Magnetic resonance in medicine (01-01-2019)“…Purpose To develop high‐spatial‐resolution cardiac T2 mapping that allows for a reduced acquisition time while maintaining its precision. We implemented and…”
Get full text
Journal Article -
16
A phantom study to determine the theoretical accuracy and precision of radial MRI to measure cross‐sectional area differences for the application of coronary endothelial function assessment
Published in Magnetic resonance in medicine (01-01-2018)“…Purpose MRI has been used to noninvasively assess coronary endothelial function by measuring the vasoreactivity in response to handgrip exercise. However, the…”
Get full text
Journal Article -
17
Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T 2 -prep for free-breathing, whole-heart coronary MRA
Published in Magnetic resonance in medicine (01-03-2018)“…In respiratory self-navigation (SN), signal from static structures, such as the chest wall, may complicate motion detection or introduce post-correction…”
Get full text
Journal Article -
18
Author Correction: Fetal cardiac cine magnetic resonance imaging in utero
Published in Scientific reports (15-05-2018)“…A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper…”
Get full text
Journal Article -
19
Respiratory optimized data selection for more resilient self-navigated whole-heart coronary MR angiography
Published in Magma (New York, N.Y.) (01-06-2017)“…Objectives Our objective was to test a data-exclusion strategy for respiratory motion suppression by retrospectively eliminating data acquired at extreme…”
Get full text
Journal Article -
20
Improved respiratory self‐navigation for 3D radial acquisitions through the use of a pencil‐beam 2D‐T2‐prep for free‐breathing, whole‐heart coronary MRA
Published in Magnetic resonance in medicine (01-03-2018)“…Purpose In respiratory self‐navigation (SN), signal from static structures, such as the chest wall, may complicate motion detection or introduce…”
Get full text
Journal Article