Search Results - "Chamberland, Marc J. P."
-
1
egs_brachy: a versatile and fast Monte Carlo code for brachytherapy
Published in Physics in medicine & biology (07-12-2016)“…egs_brachy is a versatile and fast Monte Carlo (MC) code for brachytherapy applications. It is based on the EGSnrc code system, enabling simulation of photons…”
Get more information
Journal Article -
2
Motion tracking of low‐activity fiducial markers using adaptive region of interest with list‐mode positron emission tomography
Published in Medical physics (Lancaster) (01-08-2020)“…Purpose Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic…”
Get full text
Journal Article -
3
Update of the CLRP Monte Carlo TG‐43 parameter database for high‐energy brachytherapy sources
Published in Medical physics (Lancaster) (01-03-2023)“…Purpose To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG‐43 dosimetry database (CLRP_TG43v2) for high‐energy (HE,…”
Get full text
Journal Article -
4
Update of the CLRP TG‐43 parameter database for low‐energy brachytherapy sources
Published in Medical physics (Lancaster) (01-09-2020)“…Purpose To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG‐43 dosimetry database for low‐energy (≤50 keV) photon‐emitting low‐dose rate (LDR)…”
Get full text
Journal Article -
5
Monte Carlo investigation of dose distribution of uniformly and non‐uniformly loaded standard and notched eye plaques
Published in Journal of applied clinical medical physics (01-12-2023)“…To investigate the effect of using non‐uniform loading and notched plaques on dose distribution for eye plaques. Using EGSnrc Monte Carlo (MC) simulations, we…”
Get full text
Journal Article -
6
Reply to Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'
Published in Physics in medicine & biology (02-02-2018)“…We respond to the comments by Dr Yegin by identifying the source of an error in a fit in our original paper but arguing that the lack of a fit does not affect…”
Get more information
Journal Article -
7
A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy
Published in Medical physics (Lancaster) (01-11-2017)“…A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and…”
Get full text
Journal Article -
8
Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources
Published 07-12-2022“…PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy…”
Get full text
Journal Article -
9
Update of the CLRP TG-43 parameter database for low-energy brachytherapy sources
Published 06-05-2020“…PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate…”
Get full text
Journal Article -
10
A generic TG‐186 shielded applicator for commissioning model‐based dose calculation algorithms for high‐dose‐rate 192Ir brachytherapy
Published in Medical physics (Lancaster) (01-11-2017)“…Purpose A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology…”
Get full text
Journal Article -
11
Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG 60 Co high-dose-rate brachytherapy source in a bounded water phantom
Published in Journal of contemporary brachytherapy (01-12-2019)“…The study compared the experimentally measured radial dose function, g( ), and anisotropy function, ( ,θ), of a BEBIG Co (Co0.A86) high-dose-rate (HDR) source…”
Get full text
Journal Article -
12
Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG 60Co high-dose-rate brachytherapy source in a bounded water phantom
Published in Journal of contemporary brachytherapy (01-12-2019)“…Purpose The study compared the experimentally measured radial dose function, g(r), and anisotropy function, F(r,θ), of a BEBIG 60Co (Co0.A86) high-dose-rate…”
Get full text
Journal Article -
13
A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate Ir-192 brachytherapy
Published in Medical physics (Lancaster) (2017)“…PurposeA joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology…”
Get full text
Journal Article