Search Results - "Chalmet, P"
-
1
Low-power priority Address-Encoder and Reset-Decoder data-driven readout for Monolithic Active Pixel Sensors for tracker system
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-06-2015)“…Active Pixel Sensors used in High Energy Particle Physics require low power consumption to reduce the detector material budget, low integration time to reduce…”
Get full text
Journal Article -
2
LePix—A high resistivity, fully depleted monolithic pixel detector
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2013)“…The LePix project explores monolithic pixel sensors fabricated in a 90nm CMOS technology built over a lightly doped substrate. This approach keeps the…”
Get full text
Journal Article -
3
Design and characterization of novel monolithic pixel sensors for the ALICE ITS upgrade
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-11-2014)“…Within the R&D activities for the upgrade of the ALICE Inner Tracking System (ITS), Monolithic Active Pixel Sensors (MAPS) are being developed and studied, due…”
Get full text
Journal Article -
4
LePIX: First results from a novel monolithic pixel sensor
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-08-2013)“…We present a monolithic pixel sensor developed in the framework of the LePIX project aimed at tracking/triggering tasks where high granularity, low power…”
Get full text
Journal Article -
5
Monolithic pixels on moderate resistivity substrate and sparsifying readout architecture
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2013)“…The LePix projects aim realizing a new generation monolithic pixel detectors with improved performances at lesser cost with respect to both current state of…”
Get full text
Journal Article -
6
CMOS sensors in 90 nm fabricated on high resistivity wafers: Design concept and irradiation results
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2013)“…The LePix project aims at improving the radiation hardness and the readout speed of monolithic CMOS sensors through the use of standard CMOS technologies…”
Get full text
Journal Article -
7
Severe drug allergy: The first 100 cases declared to allergy vigilance network
Published in Journal of allergy and clinical immunology (01-02-2005)“…Antibiotics [amoxicillin (40 including 1 death), cephalosporin (15), quinolones(3), bacampicillin, vancomycin (1)]; NSAID (11); paracetamol (5) ; curare (6),…”
Get full text
Journal Article -
8
CMOS sensors in 90nm fabricated on high resistivity wafers: Design concept and irradiation results
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2013)“…The LePix project aims at improving the radiation hardness and the readout speed of monolithic CMOS sensors through the use of standard CMOS technologies…”
Get full text
Journal Article -
9
VFAT2 : A front-end "system on chip" providing fast trigger information and digitized data storage for the charge sensitive readout of multi-channel silicon and gas particle detectors
Published in 2008 IEEE Nuclear Science Symposium Conference Record (01-10-2008)“…The architecture, key design parameters and results for a highly integrated front-end readout system fabricated as a single ASIC are presented. The chip…”
Get full text
Conference Proceeding -
10
Occupational contact allergy to tetrazepam
Published in Contact dermatitis (01-06-2001)Get full text
Journal Article -
11
Occupational contact allergy to tetrazepam
Published in Contact dermatitis (01-06-2001)Get full text
Journal Article -
12
Explorer-0: A Monolithic Pixel Sensor in a 180 nm CMOS process with an 18 µm thick high resistivity epitaxial layer
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…This work presents the design and characterization of Explorer-0, a Monolithic Active Pixel Sensor (MAPS) developed in the framework of the R&D activity for…”
Get full text
Conference Proceeding -
13
Anaphylactoid shock due to folinic acid during treatment of metastatic colorectal cancer
Published in Gastroentérologie clinique et biologique (01-12-2000)Get full text
Journal Article -
14
Calls to the SAMU Centre 15 (Emergency Medical Service Center 15): an indicator of peak pollen concentrations
Published in Allergie et immunologie (01-02-2001)“…A retrospective analysis of the calls received by the emergency services in Montluçon and the outpatient dossiers in the Adult and Pediatric Emergency…”
Get more information
Journal Article