Efficacy of Gutta-Percha and Polytetrafluoroethylene Tape to Microbiologically Seal the Screw Access Channel of Different Prosthetic Implant Abutments
Purpose To evaluate in vitro, the efficacy of gutta‐percha (GP) and polytetrafluoroethylene (PTFE) tape to act as a seal against the penetration of Escherichia coli through prosthetic implant abutments (PIA) with external hexagon (EH) and morse taper (MT) connections. Materials and Methods 120 sets...
Saved in:
Published in: | Clinical implant dentistry and related research Vol. 18; no. 4; pp. 778 - 787 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
Blackwell Publishing Ltd
01-08-2016
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
To evaluate in vitro, the efficacy of gutta‐percha (GP) and polytetrafluoroethylene (PTFE) tape to act as a seal against the penetration of Escherichia coli through prosthetic implant abutments (PIA) with external hexagon (EH) and morse taper (MT) connections.
Materials and Methods
120 sets of implant analogs with their respective PIA were used. 60 sets from each system were divided into four groups (n = 15): I – GP sealing; II – PTFE tape sealing; III – no sealing (NS) and IV – negative control. Microbiological challenge was performed by placing bacterial colonies inside the titanium PIA before screwing them into their respective analogs. Each set was immersed in 5 mL of BHI and incubated for 14 days with daily checks for contamination, according to the nutrient medium turbidity.
Results
The type of seal used influenced microbial penetration at all evaluation times (p < 0.05). Compared to GP, PTFE led to an increase in turbidity and its effectiveness against microbial penetration was equivalent to group NS. When the sealing efficacy of each group was compared in terms of time, Cochran's Q test revealed that in the two groups sealed with PTFE, there was a progressive increase in the number of turbid nutrient media (p < 0.0001), while in the group sealed with GP, this was only observed in the MT system (p = 0.0310).
Conclusions
Sealing the PIA channel with GP was a significantly superior approach to sealing it with PTFE tape. PTFE tape or NS led to a progressive increase in microbiological leakage over time in PIA channels, however, this only occurred with GP in the MT system. |
---|---|
Bibliography: | ark:/67375/WNG-Z4BG4WP3-8 istex:0F6CBBB8105ADBF3BEF84C4B6F9971C5B1111A77 ArticleID:CID12344 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1523-0899 1708-8208 |
DOI: | 10.1111/cid.12344 |