Search Results - "Catterson, V.M."

  • Showing 1 - 14 results of 14
Refine Results
  1. 1

    Multi-Agent Systems for Power Engineering Applications-Part I: Concepts, Approaches, and Technical Challenges by McArthur, S.D.J., Davidson, E.M., Catterson, V.M., Dimeas, A.L., Hatziargyriou, N.D., Ponci, F., Funabashi, T.

    Published in IEEE transactions on power systems (01-11-2007)
    “…This is the first part of a two-part paper that has arisen from the work of the IEEE Power Engineering Society's Multi-Agent Systems (MAS) Working Group. Part…”
    Get full text
    Journal Article
  2. 2

    Supporting group maintenance through prognostics-enhanced dynamic dependability prediction by Aizpurua, J.I., Catterson, V.M., Papadopoulos, Y., Chiacchio, F., D'Urso, D.

    Published in Reliability engineering & system safety (01-12-2017)
    “…Condition-based maintenance strategies adapt maintenance planning through the integration of online condition monitoring of assets. The accuracy and…”
    Get full text
    Journal Article
  3. 3

    Multi-Agent Systems for Power Engineering Applications-Part II: Technologies, Standards, and Tools for Building Multi-agent Systems by McArthur, S.D.J., Davidson, E.M., Catterson, V.M., Dimeas, A.L., Hatziargyriou, N.D., Ponci, F., Funabashi, T.

    Published in IEEE transactions on power systems (01-11-2007)
    “…This is the second part of a two-part paper that has arisen from the work of the IEEE Power Engineering Society's Multi-Agent Systems (MAS) Working Group. Part…”
    Get full text
    Journal Article
  4. 4

    Improved power transformer condition monitoring under uncertainty through soft computing and probabilistic health index by Aizpurua, J.I., Stewart, B.G., McArthur, S.D.J., Lambert, B., Cross, J.G., Catterson, V.M.

    Published in Applied soft computing (01-12-2019)
    “…Condition monitoring of power transformers is crucial for the reliable and cost-effective operation of the power grid. The health index (HI) formulation is a…”
    Get full text
    Journal Article
  5. 5

    Managing Remote Online Partial Discharge Data by Catterson, V.M., McArthur, S., Judd, M.D., Zaher, A.S.

    Published in IEEE transactions on power delivery (01-10-2008)
    “…The volume of data produced by existing partial discharge monitoring systems is often too large for engineers to examine in detail, leading to data being…”
    Get full text
    Journal Article
  6. 6

    Building multi-agent systems for power engineering applications by McArthur, S.D.J., Davidson, E.M., Catterson, V.M.

    “…In order to support the power engineering community in terms of effective implementation of multi-agent system technology, two key technical issues need to be…”
    Get full text
    Conference Proceeding
  7. 7

    Multi-agent systems for condition monitoring by McArthur, S.D.J., Catterson, V.M.

    “…This paper describes the benefits of using multi-agent systems for condition monitoring applications. It provides a specific example of a multi-agent system…”
    Get full text
    Conference Proceeding
  8. 8

    Investigation of radiometric partial discharge detection for use in switched HVDC testing by Judd, M.D., McArthur, S.D.J., Reid, A.J., Catterson, V.M., Li Yang, Jacobson, B., Svensson, K.O., Gunnarsson, M.

    “…This paper reports on initial trials of a non-contact radio frequency partial discharge detection technique that has potential for use within fast switching…”
    Get full text
    Conference Proceeding
  9. 9

    Integrating an Agent-Based Wireless Sensor Network within an Existing Multi-Agent Condition Monitoring System by Baker, P.C., Catterson, V.M., McArthur, S.D.J.

    “…The use of wireless sensor networks for condition monitoring is gaining ground across all sectors of industry, and while their use for power engineering…”
    Get full text
    Conference Proceeding
  10. 10

    Translating Proprietary Protection Setting Data into Standardised IEC 61850 Format for Protection Setting Validation by Hong, Q, Dys´ko, A, Booth, C.D, Catterson, V.M, Blair, S.M, Rahman, T

    “…For smart grid development, one of the key expectations is that the data should be accessible to and readily interpreted by different applications. Presently,…”
    Get full text
    Conference Proceeding
  11. 11

    On-line Transformer Condition Monitoring through Diagnostics and Anomaly Detection by Catterson, V.M., Rudd, S.E., McArthur, S.D.J., Moss, G.

    “…This paper describes the end-to-end components of an on-line system for diagnostics and anomaly detection. The system provides condition monitoring…”
    Get full text
    Conference Proceeding
  12. 12

    Issues in integrating existing multi-agent systems for power engineering applications by Catterson, V.M., Davidson, E.M., McArthur, S.D.J.

    “…Multi-agent systems (MAS) have proven to be an effective platform for diagnostic and condition monitoring applications in the power industry. For example, a…”
    Get full text
    Conference Proceeding
  13. 13

    Design of an intelligent diagnostic architecture to support the condition monitoring of power generation assets by Kenyon, A.D., Catterson, V.M., McArthur, S.D.J., Twiddle, J.

    “…Detailed, timely and accurate condition monitoring and diagnostic capability for generation assets is important for safely operating a power plant. A software…”
    Get full text
    Conference Proceeding
  14. 14

    The practical implications of bringing a multi-agent transformer condition monitoring system on-line by Catterson, V.M., McArthur, S.D.J.

    “…On-line condition monitoring is a useful tool for maintaining and extending the longevity of power transformers. An intelligent diagnostic system is desirable…”
    Get full text
    Conference Proceeding