Search Results - "Carter, Timothy J.N."
-
1
Modification of a piezo-optical gas dosimeter system towards continuous gas sensing: a feasibility study with carbon dioxide
Published in Sensors and actuators. B, Chemical (20-04-2003)“…We report a feasibility study of monitoring gases continuously by means of an adapted piezo-optical dosimeter system. The test gas is carbon dioxide whose…”
Get full text
Journal Article -
2
A novel piezo-optical styrene sensor incorporating polymer-supported tribromide ion
Published in Chemical communications (Cambridge, England) (07-05-2002)“…Encapsulation of Amberlyst A-26 supported tribromide in a 10,000 MW polyethylene glycol matrix gives a robust colour-sensitive reagent matrix which can be…”
Get more information
Journal Article -
3
Development of a piezo-optical chemical monitoring system for nitrogen dioxide
Published in Sensors and actuators. B, Chemical (31-08-1998)“…A new environmental and occupational chemical monitoring system for measurement of nitrogen dioxide exposures in the range 10 ppb–10 ppm per h is reported. The…”
Get full text
Journal Article -
4
Kinetic factors in the response of piezo-optical chemical monitoring devices
Published in Sensors and actuators. B, Chemical (31-08-1998)“…The dependence of the amplitude, phase lag and shape of the response of a novel piezo-optical monitoring system on the thickness and the geometry of colour…”
Get full text
Journal Article -
5
Development of a piezo-optical chemical monitoring system
Published in Sensors and actuators. B, Chemical (31-08-1998)“…The development of an environmental and occupational chemical monitoring system based on a piezoelectric polymer film badge is described. Colour changes in…”
Get full text
Journal Article -
6
Enhanced luminescence procedure for sensitive determination of peroxidase-labelled conjugates in immunoassay
Published in Nature (London) (01-01-1983)Get full text
Journal Article -
7
Thermal characteristics of microtitre plates used in immunological assays
Published in Journal of immunological methods (01-01-1979)“…Thermal studies of various types of microtitre plate have shown that wells at the edges of a plate have different thermal characteristics from those in the…”
Get more information
Journal Article -
8
Instrumentation
Published in Clinical biochemistry (01-12-1983)Get more information
Journal Article -
9
A method for enhancing the stability of thiol-containing enzymes immobilised on nylon
Published in Clinica chimica acta (15-08-1977)“…The limited stability of immobilised enzymes is a major factor restricting their use in clinical chemistry. The immobilisation procedure described here affords…”
Get more information
Journal Article