Search Results - "Campíns Falcó, P."

Refine Results
  1. 1

    Magnetic In-Tube Solid Phase Microextraction by Moliner-Martínez, Y, Prima-Garcia, Helena, Ribera, Antonio, Coronado, Eugenio, Campíns-Falcó, P

    Published in Analytical chemistry (Washington) (21-08-2012)
    “…We report a new in-tube solid phase microextraction approach named magnetic in-tube solid phase microextraction, magnetic-IT-SPME. Magnetic-IT-SPME has been…”
    Get full text
    Journal Article
  2. 2

    Miniaturized liquid chromatography in environmental analysis. A review by Cortés-Bautista, S., Molins-Legua, C., Campíns-Falcó, P.

    Published in Journal of Chromatography A (16-08-2024)
    “…•The miniaturization of HPLC, thought c-LC and n-LC provide green methodologies.•The LC sample treatment can be performed on-line and off-line.•IT- SPME…”
    Get full text
    Journal Article
  3. 3

    Minimizing the impact of sample preparation on analytical results: In-tube solid-phase microextraction coupled on-line to nano-liquid chromatography for the monitoring of tribenuron methyl in environmental waters by Serra-Mora, P., Herráez-Hernández, R., Campíns-Falcó, P.

    Published in The Science of the total environment (15-06-2020)
    “…The degradation kinetics and residual levels of the sulfonylurea herbicide tribenuron-methyl (TBM) in different environmental waters were studied using in…”
    Get full text
    Journal Article
  4. 4

    Recent advances of in-tube solid-phase microextraction by Moliner-Martinez, Y., Herráez-Hernández, R., Verdú-Andrés, J., Molins-Legua, C., Campíns-Falcó, P.

    “…•In-tube solid-phase microextraction (SPME) is green approach to sample preparation.•Review of operational devices used for in-tube solid-phase microextraction…”
    Get full text
    Journal Article
  5. 5

    Bimodal copper oxide nanoparticles doped phase for the extraction of highly polar compounds by in-tube solid-phase microextraction coupled on-line to nano-liquid chromatography by Serra-Mora, P., Herráez-Hernández, R., Campíns-Falcó, P.

    Published in Journal of Chromatography A (26-04-2020)
    “…•Polymers with different metal and metal oxide nanoparticles have been synthetized.•They have been used for in-tube solid-phase microextraction – nano…”
    Get full text
    Journal Article
  6. 6

    Plasmonic sensor for hydrogen sulphide in saliva: Multisensor platform and bag format by Carrero-Ferrer, I., Molins-Legua, C., Campíns-Falcó, P.

    Published in Talanta (Oxford) (01-08-2022)
    “…In recent years, there is a growing demand for optical sensors given their analytical properties, and the possibility of in situ implementation. Among all the…”
    Get full text
    Journal Article
  7. 7

    In tube-solid phase microextraction-nano liquid chromatography: Application to the determination of intact and degraded polar triazines in waters and recovered struvite by Serra-Mora, P., Jornet-Martinez, N., Moliner-Martinez, Y., Campíns-Falcó, P.

    Published in Journal of Chromatography A (01-09-2017)
    “…•On-line coupling in nano liquid chromatography is proposed.•Several phases containing nanomaterials are assayed.•Improved results are obtained for…”
    Get full text
    Journal Article
  8. 8

    Scopolamine analysis in beverages: Bicolorimetric device vs portable nano liquid chromatography by Jornet-Martínez, N., Herráez-Hernández, R., Campíns-Falcó, P.

    Published in Talanta (Oxford) (01-09-2021)
    “…Scopolamine (SCP) is often involved in sexual assaults and robberies, particularly in recreational environments. Therefore, analytical tools are required for…”
    Get full text
    Journal Article
  9. 9
  10. 10

    A modified micro-solid phase extraction device for in-port elution and injection into portable liquid chromatography: A proof-of-concept study by Rodríguez-Palma, C.E., Herráez-Hernández, R., Campíns-Falcó, P.

    Published in Journal of Chromatography A (30-08-2023)
    “…•A micro-solid phase extraction device for portable liquid chromatography is shown.•The device uses 10 mg of C18 sorbent immobilized on a modified syringe…”
    Get full text
    Journal Article
  11. 11

    Footprint of carbonyl compounds in hand scent by in-tube solid-phase microextraction coupled to nano-liquid chromatography/diode array detection by Prieto-Blanco, M.C., Peñafiel Barba, S., Moliner-Martínez, Y., Campíns-Falcó, P.

    Published in Journal of Chromatography A (05-07-2019)
    “…•Rapid footprint of the carbonyl compounds in hand scent was achieved.•Two-valves- IT-SPME-nanoLC-DAD was proposed to get the chromatographic profiles.•Rapid…”
    Get full text
    Journal Article
  12. 12

    Towards in field miniaturized liquid chromatography: Biocides in wastewater as a proof of concept by Cortés-Bautista, S., Navarro-Utiel, R., Ballester-Caudet, A., Campíns-Falcó, P.

    Published in Journal of Chromatography A (21-06-2022)
    “…•Capabilities of a portable miniaturized LC for in-field analysis were studied.•Portable LC and benchtop capillary and nano LCs were tested.•BETTER criteria…”
    Get full text
    Journal Article
  13. 13

    Quantitative study of the capture of silver nanoparticles by several kinds of soils by González-Fuenzalida, R.A., Sanjuan-Navarro, L., Moliner-Martínez, Y., Campíns-Falcó, P.

    Published in The Science of the total environment (15-07-2018)
    “…The capacity of different soils to capture silver nanoparticles (AgNPs) by measuring changes of an AgNP intrinsic property such as the plasmon for the first…”
    Get full text
    Journal Article
  14. 14
  15. 15
  16. 16

    Ionic-liquid doped polymeric composite as passive colorimetric sensor for meat freshness as a use case by Ballester-Caudet, A., Hakobyan, L., Moliner-Martinez, Y., Molins-Legua, C., Campíns-Falcó, P.

    Published in Talanta (Oxford) (01-02-2021)
    “…A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl…”
    Get full text
    Journal Article
  17. 17

    Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case by Ponce-Rodríguez, H.D., Verdú-Andrés, J., Herráez-Hernández, R., Campíns-Falcó, P.

    Published in The Science of the total environment (10-12-2020)
    “…Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established…”
    Get full text
    Journal Article
  18. 18
  19. 19

    Preconcentration of emerging contaminants in environmental water samples by using silica supported Fe₃O₄ magnetic nanoparticles for improving mass detection in capillary liquid chromatography by Moliner-Martínez, Yolanda, Ribera, Antonio, Coronado, Eugenio, Campíns-Falcó, P

    Published in Journal of Chromatography A (22-04-2011)
    “…A magnetic material based on Fe₃O₄ magnetic nanoparticles incorporated in a silica matrix by using a sol–gel procedure has been used to extract and…”
    Get full text
    Journal Article
  20. 20

    In-tube solid phase microextraction coupled to miniaturized liquid chromatography for both, noble metal nanoparticle assessment and sensitive plasmonic assay development by Sanjuan-Navarro, L., Cortés-Bautista, S., Moliner-Martínez, Y., Campíns-Falcó, P.

    Published in Analytica chimica acta (01-08-2021)
    “…Colorimetric localized surface plasmon resonance (LSPR) as analytical response is applied for a wide number of chemical sensors and biosensors. However, the…”
    Get full text
    Journal Article