Search Results - "Bruder, Herbert"

Refine Results
  1. 1

    Material differentiation by dual energy CT: initial experience by Johnson, Thorsten R C, Krauss, Bernhard, Sedlmair, Martin, Grasruck, Michael, Bruder, Herbert, Morhard, Dominik, Fink, Christian, Weckbach, Sabine, Lenhard, Miriam, Schmidt, Bernhard, Flohr, Thomas, Reiser, Maximilian F, Becker, Christoph R

    Published in European radiology (01-06-2007)
    “…The aim of this study was to assess the feasibility of a differentiation of iodine from other materials and of different body tissues using dual energy CT. Ten…”
    Get full text
    Journal Article
  2. 2

    First performance evaluation of a dual-source CT (DSCT) system by Flohr, Thomas G, McCollough, Cynthia H, Bruder, Herbert, Petersilka, Martin, Gruber, Klaus, Süss, Christoph, Grasruck, Michael, Stierstorfer, Karl, Krauss, Bernhard, Raupach, Rainer, Primak, Andrew N, Küttner, Axel, Achenbach, Stefan, Becker, Christoph, Kopp, Andreas, Ohnesorge, Bernd M

    Published in European radiology (01-02-2006)
    “…We present a performance evaluation of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding…”
    Get full text
    Journal Article
  3. 3
  4. 4

    Contrast-enhanced coronary artery visualization by dual-source computed tomography—Initial experience by Achenbach, Stephan, Ropers, Dieter, Kuettner, Axel, Flohr, Thomas, Ohnesorge, Bernd, Bruder, Herbert, Theessen, Heike, Karakaya, Meri, Daniel, Werner G., Bautz, Werner, Kalender, Willi A., Anders, Katharina

    Published in European journal of radiology (01-03-2006)
    “…Multi-detector computed tomography (CT) scanners, by virtue of their high temporal and spatial resolution, permit imaging of the coronary arteries. However,…”
    Get full text
    Journal Article
  5. 5

    Cardiac CT: How much can temporal resolution, spatial resolution, and volume coverage be improved? by Flohr, Thomas G., PhD, Raupach, Rainer, PhD, Bruder, Herbert, PhD

    “…Abstract In this article, we review the current status and discuss potential further improvements and limitations of system parameters relevant for cardiac CT,…”
    Get full text
    Journal Article
  6. 6

    Technical principles of dual source CT by Petersilka, Martin, Bruder, Herbert, Krauss, Bernhard, Stierstorfer, Karl, Flohr, Thomas G

    Published in European journal of radiology (01-12-2008)
    “…Abstract During the past years, multi-detector row CT (MDCT) has evolved into clinical practice with a rapid increase of the number of detector slices. Today's…”
    Get full text
    Journal Article
  7. 7

    Motion compensation in the region of the coronary arteries based on partial angle reconstructions from short‐scan CT data by Hahn, Juliane, Bruder, Herbert, Rohkohl, Christopher, Allmendinger, Thomas, Stierstorfer, Karl, Flohr, Thomas, Kachelrieß, Marc

    Published in Medical physics (Lancaster) (01-11-2017)
    “…Purpose In order to mitigate motion‐induced artifacts, several motion compensation (MoCo) methods have been developed, which are either able to (a) compensate…”
    Get full text
    Journal Article
  8. 8

    Improving best-phase image quality in cardiac CT by motion correction with MAM optimization by Rohkohl, Christopher, Bruder, Herbert, Stierstorfer, Karl, Flohr, Thomas

    Published in Medical physics (Lancaster) (01-03-2013)
    “…Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The…”
    Get full text
    Journal Article
  9. 9

    Dose performance of a 64-channel dual-source CT scanner by McCollough, Cynthia H, Primak, Andrew N, Saba, Osama, Bruder, Herbert, Stierstorfer, Karl, Raupach, Rainer, Suess, Christoph, Schmidt, Bernhard, Ohnesorge, Bernd M, Flohr, Thomas G

    Published in Radiology (01-06-2007)
    “…To prospectively compare the dose performance of a 64-channel multi-detector row computed tomographic (CT) scanner and a 64-channel dual-source CT scanner from…”
    Get more information
    Journal Article
  10. 10

    Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality by Flohr, Thomas G., Leng, Shuai, Yu, Lifeng, Allmendinger, Thomas, Bruder, Herbert, Petersilka, Martin, Eusemann, Christian D., Stierstorfer, Karl, Schmidt, Bernhard, McCollough, Cynthia H.

    Published in Medical physics (Lancaster) (01-12-2009)
    “…Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its…”
    Get full text
    Journal Article
  11. 11

    Multi-detector row CT systems and image-reconstruction techniques by Flohr, Thomas G, Schaller, Stefan, Stierstorfer, Karl, Bruder, Herbert, Ohnesorge, Bernd M, Schoepf, U Joseph

    Published in Radiology (01-06-2005)
    “…The introduction in 1998 of multi-detector row computed tomography (CT) by the major CT vendors was a milestone with regard to increased scan speed, improved…”
    Get more information
    Journal Article
  12. 12

    Temporal resolution and motion artifacts in single-source and dual-source cardiac CT by Schöndube, Harald, Allmendinger, Thomas, Stierstorfer, Karl, Bruder, Herbert, Flohr, Thomas

    Published in Medical physics (Lancaster) (01-03-2013)
    “…Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for…”
    Get full text
    Journal Article
  13. 13

    Weighted FBP--a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch by Stierstorfer, Karl, Rauscher, Annabella, Boese, Jan, Bruder, Herbert, Schaller, Stefan, Flohr, Thomas

    Published in Physics in medicine & biology (07-06-2004)
    “…A new 3D reconstruction scheme, weighted filtered backprojection (WFBP) for multirow spiral CT based on an extension of the two-dimensional SMPR algorithm is…”
    Get more information
    Journal Article
  14. 14

    Pushing the Envelope: New Computed Tomography Techniques for Cardiothoracic Imaging by Flohr, Thomas G, Klotz, Ernst, Allmendinger, Thomas, Raupach, Rainer, Bruder, Herbert, Schmidt, Bernhard

    Published in Journal of thoracic imaging (01-05-2010)
    “…Multidetector row computed tomography (MDCT) has been used for cardiothoracic imaging since the advent of 4-slice computed tomography (CT) in 1999. Available…”
    Get full text
    Journal Article
  15. 15
  16. 16

    Measurement of temporal resolution in dual source CT by McCollough, Cynthia H., Schmidt, Bernhard, Yu, Lifeng, Primak, Andrew, Ulzheimer, Stefan, Bruder, Herbert, Flohr, Thomas G.

    Published in Medical physics (Lancaster) (01-02-2008)
    “…This work assesses the temporal resolution of dual-source computed tomography (CT) in a visually intuitive manner. Exploiting the principles of ring artifact…”
    Get full text
    Journal Article
  17. 17

    Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT by Stenner, Philip, Schmidt, Bernhard, Bruder, Herbert, Allmendinger, Thomas, Haberland, Ulrike, Flohr, Thomas, Kachelrieß, Marc

    Published in Medical physics (Lancaster) (01-12-2009)
    “…Purpose: Cardiac CT achieves its high temporal resolution by lowering the scan range from 2 π to π plus fan angle (partial scan). This, however, introduces…”
    Get full text
    Journal Article
  18. 18

    Advances in cardiac imaging with 16-section CT systems by Flohr, Thomas G, Schoepf, U Joseph, Kuettner, Axel, Halliburton, Sandra, Bruder, Herbert, Suess, Christoph, Schmidt, Bernhard, Hofmann, Lars, Yucel, Edgar Kent, Schaller, Stefan, Ohnesorge, Bernd M

    Published in Academic radiology (01-04-2003)
    “…The authors present advances in electrocardiographically (ECG) gated cardiac spiral scanning with recently introduced 16-section computed tomographic (CT)…”
    Get more information
    Journal Article
  19. 19

    Segmented multiple plane reconstruction: a novel approximate reconstruction scheme for multi-slice spiral CT by Stierstorfer, Karl, Flohr, Thomas, Bruder, Herbert

    Published in Physics in medicine & biology (07-08-2002)
    “…A new reconstruction scheme for multi-row spiral CT is described and results are presented. The spiral path is decomposed into small, overlapping segments…”
    Get more information
    Journal Article
  20. 20

    Dual-Source Computed Tomography for Assessing Cardiac Function: A Phantom Study by Mahnken, Andreas H, Bruder, Herbert, Suess, Christoph, Mühlenbruch, Georg, Bruners, Philipp, Hohl, Christian, Guenther, Rolf W, Wildberger, Joachim E

    Published in Investigative radiology (01-07-2007)
    “…PURPOSE:To investigate the influence of heart rate and temporal resolution on the assessment of global ventricular function with dual-source computed…”
    Get full text
    Journal Article