Search Results - "Broch, S."

Refine Results
  1. 1

    Recent advances on ionic liquid uses in separation techniques by Berthod, A., Ruiz-Ángel, M.J., Carda-Broch, S.

    Published in Journal of Chromatography A (20-07-2018)
    “…•Ionic liquids as solvents in nuclear waste reprocessing.•Ionic liquids as polar and thermally stable stationary phases for gas chromatoraphy.•Ionic liquids…”
    Get full text
    Journal Article
  2. 2

    Determination of liquid–liquid partition coefficients by separation methods by Berthod, A, Carda-Broch, S

    Published in Journal of Chromatography A (28-05-2004)
    “…By essence, all kinds of chromatographic methods use the partitioning of solutes between a stationary and a mobile phase to separate them. Not surprisingly,…”
    Get full text
    Book Review Journal Article
  3. 3

    Ionic liquids in separation techniques by Berthod, A., Ruiz-Ángel, M.J., Carda-Broch, S.

    Published in Journal of Chromatography A (14-03-2008)
    “…The growing interest in ionic liquids (ILs) has resulted in an exponentially increasing production of analytical applications. The potential of ILs in…”
    Get full text
    Journal Article
  4. 4

    On the use of ionic liquids as mobile phase additives in high-performance liquid chromatography. A review by García-Alvarez-Coque, M.C., Ruiz-Angel, M.J., Berthod, A., Carda-Broch, S.

    Published in Analytica chimica acta (09-07-2015)
    “…[Display omitted] •Up-dated information on HPLC procedures using ionic liquids as additives.•Description of the different interactions of stationary phase and…”
    Get full text
    Journal Article
  5. 5

    Solvent properties of the 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid by Carda-Broch, S, Berthod, A, Armstrong, D W

    Published in Analytical and bioanalytical chemistry (01-01-2003)
    “…1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF(6)) was synthesized and purified to be used as a ionic liquid solvent. Its physicochemical properties…”
    Get full text
    Journal Article
  6. 6

    Use of micellar liquid chromatography to analyze oxolinic acid, flumequine, marbofloxacin and enrofloxacin in honey and validation according to the 2002/657/EC decision by Tayeb-Cherif, K., Peris-Vicente, J., Carda-Broch, S., Esteve-Romero, J.

    Published in Food chemistry (01-07-2016)
    “…•In this study, we analyze OXO, FLU, MARBO and ENRO in honey.•MLC-based approach was fast, easy, reliable, safe inexpensive and eco friendly.•The experimental…”
    Get full text
    Journal Article
  7. 7

    Extent of the influence of phosphate buffer and ionic liquids on the reduction of the silanol effect in a C18 stationary phase by Carda-Broch, S., García-Alvarez-Coque, M.C., Ruiz-Angel, M.J.

    Published in Journal of Chromatography A (20-07-2018)
    “…•The effect of buffer concentration and pH on retention and peak shape is studied.•Mobile phases in the absence and presence of imidazolium ionic liquids are…”
    Get full text
    Journal Article
  8. 8

    Analysis of selected veterinary antibiotics in fish by micellar liquid chromatography with fluorescence detection and validation in accordance with regulation 2002/657/EC by Rambla-Alegre, M., Peris-Vicente, J., Esteve-Romero, J., Carda-Broch, S.

    Published in Food chemistry (15-12-2010)
    “…A simple and sensitive method was optimised and validated for the simultaneous analysis of five quinolones (oxolinic acid, flumequine, enrofloxacin, difloxacin…”
    Get full text
    Journal Article
  9. 9

    Effect of buffer nature and concentration on the chromatographic performance of basic compounds in the absence and presence of 1-hexyl-3-methylimidazolium chloride by Peris-García, E., García-Alvarez-Coque, M.C., Carda-Broch, S., Ruiz-Angel, M.J.

    Published in Journal of Chromatography A (27-09-2019)
    “…•The effect on retention and peak shape of four buffer systems is studied.•Mobile phases in the absence and presence of ionic liquid are compared.•Buffers have…”
    Get full text
    Journal Article
  10. 10

    Modulation of retention and selectivity in oil-in-water microemulsion liquid chromatography: A review by Pankajkumar-Patel, N., Peris-García, E., Ruiz-Angel, M.J., Carda-Broch, S., García-Alvarez-Coque, M.C.

    Published in Journal of Chromatography A (10-05-2019)
    “…•Modulation of retention in microemulsion liquid chromatography is described.•The contents of reagents for best retention, selectivity and resolution are…”
    Get full text
    Journal Article
  11. 11
  12. 12

    Retention mechanisms in micellar liquid chromatography by Ruiz-Ángel, M.J., Carda-Broch, S., Torres-Lapasió, J.R., García-Álvarez-Coque, M.C.

    Published in Journal of Chromatography A (06-03-2009)
    “…Micellar liquid chromatography (MLC) is a reversed-phase liquid chromatographic (RPLC) mode with mobile phases containing a surfactant (ionic or non-ionic)…”
    Get full text
    Journal Article
  13. 13

    Countercurrent chromatography: People and applications by Berthod, A., Ruiz-Ángel, M.J., Carda-Broch, S.

    Published in Journal of Chromatography A (08-05-2009)
    “…The scientific literature was scanned for the published research articles dealing with countercurrent chromatography (CCC) over the time period 1980-May 2008…”
    Get full text
    Journal Article Conference Proceeding
  14. 14

    Ionic liquids versus triethylamine as mobile phase additives in the analysis of β-blockers by Ruiz-Angel, M.J., Carda-Broch, S., Berthod, A.

    Published in Journal of Chromatography A (30-06-2006)
    “…A comparative study of peak shape, elution behavior, elution strength and resolution of seven β-blockers (acebutolol, alprenolol, labetalol, metoprolol,…”
    Get full text
    Journal Article Conference Proceeding
  15. 15

    Isoprene in poplar emissions: effects on new particle formation and OH concentrations by Kiendler-Scharr, A, Andres, S, Bachner, M, Behnke, K, Broch, S, Hofzumahaus, A, Holland, F, Kleist, E, Mentel, T. F, Rubach, F, Springer, M, Steitz, B, Tillmann, R, Wahner, A, Schnitzler, J.-P, Wildt, J

    Published in Atmospheric chemistry and physics (20-01-2012)
    “…Stress-induced volatile organic compound (VOC) emissions from transgenic Grey poplar modified in isoprene emission potential were used for the investigation of…”
    Get full text
    Journal Article
  16. 16

    Use of the ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate in countercurrent chromatography by Berthod, A, Carda-Broch, S

    Published in Analytical and bioanalytical chemistry (01-09-2004)
    “…Room temperature ionic liquids (RTIL) are molten salts that are liquids at room temperature. Their liquid state makes them possible candidates as solvents in…”
    Get full text
    Journal Article
  17. 17

    Performance of different C18 columns in reversed-phase liquid chromatography with hydro-organic and micellar-organic mobile phases by Ruiz-Angel, M.J., Pous-Torres, S., Carda-Broch, S., García-Alvarez-Coque, M.C.

    Published in Journal of Chromatography A (30-05-2014)
    “…•C18 columns show significant difference in behaviour for basic compounds.•SDS monomers cover the stationary phase reducing the silanol effect.•Evaluation of…”
    Get full text
    Journal Article
  18. 18

    Half-width plots, a simple tool to predict peak shape, reveal column kinetics and characterise chromatographic columns in liquid chromatography: State of the art and new results by Baeza-Baeza, J.J., Ruiz-Ángel, M.J., García-Álvarez-Coque, M.C., Carda-Broch, S.

    Published in Journal of Chromatography A (01-11-2013)
    “…•Half-width plots: simple tool representing the information of chromatograms.•Protocols to obtain half-width plots in isocratic and gradient modes.•Use of…”
    Get full text
    Journal Article Conference Proceeding
  19. 19

    Are analysts doing method validation in liquid chromatography? by Ruiz-Angel, M.J., García-Alvarez-Coque, M.C., Berthod, A., Carda-Broch, S.

    Published in Journal of Chromatography A (01-08-2014)
    “…•Survey on how well analysts are doing method validation in the field of liquid chromatography in recent years.•The characteristics of method validation are…”
    Get full text
    Journal Article
  20. 20

    Peak half-width plots to study the effect of organic solvents on the peak performance of basic drugs in micellar liquid chromatography by Ruiz-Ángel, M.J., Carda-Broch, S., García-Álvarez-Coque, M.C.

    Published in Journal of Chromatography A (12-03-2010)
    “…The addition of the anionic surfactant sodium dodecyl sulphate (SDS) to hydro-organic mixtures of methanol, ethanol, propanol or acetonitrile with water…”
    Get full text
    Journal Article