Search Results - "Borman, T."
-
1
Carbon stoichiometry and mechanical properties of high entropy carbides
Published in Acta materialia (15-08-2021)“…The search for new materials via compositional exploration has recently led to the discovery of entropy stabilized and high entropy ceramics. The chemical…”
Get full text
Journal Article -
2
First experimental exploration of real-time cardiorespiratory motion management for future stereotactic arrhythmia radioablation treatments on the MR-linac
Published in Physics in medicine & biology (09-03-2022)“…Stereotactic arrhythmia radioablation (STAR) is a novel, non-invasive treatment for refractory ventricular tachycardia (VT). The VT isthmus is subject to both…”
Get more information
Journal Article -
3
Characterization of imaging latency for real-time MRI-guided radiotherapy
Published in Physics in medicine & biology (06-08-2018)“…Hybrid MR-linac systems can use fast dynamic MR sequences for tumor tracking and adapt the radiation treatment in real-time. For this the imaging latency must…”
Get more information
Journal Article -
4
First experimental demonstration of VMAT combined with MLC tracking for single and multi fraction lung SBRT on an MR-linac
Published in Radiotherapy and oncology (01-09-2022)“…•Successful experimental demonstration of VMAT combined with MRI-guided MLC tracking.•MLC tracking on the MR-linac has clear dosimetric advantages for lung…”
Get full text
Journal Article -
5
Dosimetric evaluation of MRI‐guided multi‐leaf collimator tracking and trailing for lung stereotactic body radiation therapy
Published in Medical physics (Lancaster) (01-04-2021)“…Purpose The treatment margins for lung stereotactic body radiotherapy (SBRT) are often large to cover the tumor excursions resulting from respiration, such…”
Get full text
Journal Article -
6
A hybrid 2D/4D‐MRI methodology using simultaneous multislice imaging for radiotherapy guidance
Published in Medical physics (Lancaster) (01-09-2022)“…Purpose Respiratory motion management is important in abdominothoracic radiotherapy. Fast imaging of the tumor can facilitate multileaf collimator (MLC)…”
Get full text
Journal Article -
7
Effectiveness of visual biofeedback–guided respiratory‐correlated 4D‐MRI for radiotherapy guidance on the MR‐linac
Published in Magnetic resonance in medicine (01-01-2024)“…Purpose Respiratory‐correlated 4D‐MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated…”
Get full text
Journal Article -
8
Experimental demonstration of real‐time cardiac physiology‐based radiotherapy gating for improved cardiac radioablation on an MR‐linac
Published in Medical physics (Lancaster) (01-04-2024)“…Background Cardiac radioablation is a noninvasive stereotactic body radiation therapy (SBRT) technique to treat patients with refractory ventricular…”
Get full text
Journal Article -
9
Evaluation of the impact of cardiac implantable electronic devices on cine MRI for real-time adaptive cardiac radioablation on a 1.5 T MR-linac
Published in Medical physics (Lancaster) (04-10-2024)“…Stereotactic arrhythmia radioablation (STAR) is a novel treatment approach for refractory ventricular tachycardia (VT). The risk of treatment-induced toxicity…”
Get full text
Journal Article -
10
ReconSocket: a low-latency raw data streaming interface for real-time MRI-guided radiotherapy
Published in Physics in medicine & biology (17-09-2019)“…With the recent advent of hybrid MRI-guided radiotherapy systems, continuous intra-fraction MR imaging for motion monitoring has become feasible. The ability…”
Get more information
Journal Article -
11
Gating and intrafraction drift correction on a 1.5 T MR-Linac: Clinical dosimetric benefits for upper abdominal tumors
Published in Radiotherapy and oncology (01-12-2023)“…•First treatments with active motion management on a 1.5 T MR-Linac.•Image-based target tracking for gating and tumor drift correction.•Motion management…”
Get full text
Journal Article -
12
Arterial spin labeling using spatio‐temporal encoding readout for robust perfusion imaging in inhomogenous magnetic fields
Published in Magnetic resonance in medicine (01-03-2023)“…Purpose To evaluate the feasibility of spatio‐temporal encoding (SPEN) readout for pseudo‐continuous ASL (pCASL) in brain, and its robustness to susceptibility…”
Get full text
Journal Article -
13
Assessment of 3D motion modeling performance for dose accumulation mapping on the MR-linac by simultaneous multislice MRI
Published in Physics in medicine & biology (23-04-2019)“…Hybrid MR-linac systems enable intrafraction motion monitoring during radiation therapy. Since time-resolved 3D MRI is still challenging, various motion models…”
Get more information
Journal Article -
14
Coupling quantum corrals to form artificial molecules
Published in SciPost physics (10-12-2020)“…Quantum corrals can be considered artificial atoms. By coupling many quantum corrals together, artificial matter can be created at will. The atomic scale…”
Get full text
Journal Article -
15
Towards real-time thermometry using simultaneous multislice MRI
Published in Physics in medicine & biology (07-09-2016)“…MR-guided thermal therapies, such as high-intensity focused ultrasound (MRgHIFU) and laser-induced thermal therapy (MRgLITT) are increasingly being applied in…”
Get more information
Journal Article -
16
On Patient Experience and Anxiety During Treatment With Magnetic Resonance–Guided Radiation Therapy
Published in Advances in radiation oncology (01-08-2024)“…To assess patient experience and anxiety during magnetic resonance (MR)–guided radiation therapy (MRgRT) using a hybrid 1.5Tesla (T) MR-guided linear…”
Get full text
Journal Article -
17
Feasibility of cardiac-synchronized quantitative T 1 and T 2 mapping on a hybrid 1.5 Tesla magnetic resonance imaging and linear accelerator system
Published in Physics and imaging in radiation oncology (01-01-2022)“…The heart is important in radiotherapy either as target or organ at risk. Quantitative T and T cardiac magnetic resonance imaging (qMRI) may aid in target…”
Get full text
Journal Article -
18
MR imaging of mediastinal lymph nodes: Evaluation using a superparamagnetic contrast agent
Published in Journal of magnetic resonance imaging (01-12-2000)“…The purpose of this study was to determine whether intravenous injection of a magnetic resonance (MR) contrast agent, ultrasmall superparamagnetic iron oxide…”
Get full text
Journal Article -
19
Bedside orthopedic procedures
Published in Critical care clinics (01-01-2000)“…Orthopedic bedside procedures commonly are performed and are appropriate. As the complexity of patient needs increases and resources are stretched, more…”
Get more information
Journal Article -
20
Immunomodulator OM 163-induced reversal of tumor-mediated immunosuppression and downregulation of TGF-beta 1 in vivo
Published in The Journal of pharmacology and experimental therapeutics (01-08-1996)“…Although PROb colonic tumor cells are immunosuppressive, the immunomodulator OM 163 induced the disappearance of macroscopic peritoneal nodules in 50% of rats…”
Get more information
Journal Article