Search Results - "Bordy, Jean Marc"
-
1
Defining field output factors in small fields based on dose area product measurements: A feasibility study
Published in Medical physics (Lancaster) (01-05-2024)“…Background Dose area product in water (DAPw) in small fields relies on the use of detectors with a sensitive area larger than the irradiation field. This…”
Get full text
Journal Article -
2
Photon dosimetry methods outside the target volume in radiation therapy: Optically stimulated luminescence (OSL), thermoluminescence (TL) and radiophotoluminescence (RPL) dosimetry
Published in Radiation measurements (01-10-2013)“…Dosimetry methods outside the target volume are still not well established in radiotherapy. Luminescence detectors due to their small dimensions, very good…”
Get full text
Journal Article Conference Proceeding -
3
Report of IRPA task group on issues and actions taken in response to the change in eye lens dose limit
Published in Journal of radiological protection (01-12-2020)“…In 2018, the International Radiation Protection Association (IRPA) established its third task group (TG) on the implementation of the eye lens dose limit. To…”
Get more information
Journal Article -
4
Clinical simulations of prostate radiotherapy using BOMAB-like phantoms: Results for photons
Published in Radiation measurements (01-10-2013)“…In this part of work carried out by Working Group 9 (Radiation Protection Dosimetry in Medicine) of the European Radiation Dosimetry Group (EURADOS), water…”
Get full text
Journal Article Conference Proceeding -
5
Dose verification and calibration of the Cyberknife ® by EPR/alanine dosimetry
Published in Radiation measurements (01-09-2011)“…Standard calibration protocols in radiotherapy (AAPM TG-51 and IAEA TRS 398) recommend a 10 × 10 cm 2 irradiation field at a distance of 100 cm. However, the…”
Get full text
Journal Article -
6
Calibration of helical tomotherapy machine using EPR/alanine dosimetry
Published in Medical physics (Lancaster) (01-03-2011)“…Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10 × 10 cm 2…”
Get full text
Journal Article -
7
Fricke-Xylenol orange-Gelatin gel characterization with dual wavelength cone-beam optical CT scanner for applications in stereotactic and dynamic radiotherapy
Published in Physica medica (01-05-2022)“…•A FXG gel composition is optimized for stereotactic and dynamic radiotherapy.•A new dual wavelength reading method of FXG gel is developed on a CT…”
Get full text
Journal Article -
8
Opening address
Published in EPJ Web of Conferences (01-01-2016)Get full text
Journal Article Conference Proceeding -
9
End-to-end quality assurance for stereotactic radiotherapy with Fricke-Xylenol orange-Gelatin gel dosimeter and dual-wavelength cone-beam optical CT readout
Published in Physica medica (01-09-2023)“…•Three-dimensional end-to-end quality assurance tests have been implemented.•FXG gel dosimeters were used with a new dual-wavelength optical CT readout.•Three…”
Get full text
Journal Article -
10
Preliminary dosimetric characterization of EDBreast gel
Published in Biomedical physics & engineering express (01-09-2023)“… EDBreast gel is an alternative Fricke gel dosimeter, read by Magnetic Resonance Imaging, in which sucrose is added to lower diffusion effects. This paper…”
Get more information
Journal Article -
11
Dose area product primary standards established by graphite calorimetry at the LNE-LNHB for small radiation fields in radiotherapy
Published in Physica medica (01-06-2022)“…•Lack of primary standards for small fields.•Dose Area Product (DAP) is used to overcome the point dose traceability breakdown.•Primary standards in terms of…”
Get full text
Journal Article -
12
Out-of-field dose measurements in radiotherapy – An overview of activity of EURADOS Working Group 9: Radiation protection in medicine
Published in Radiation measurements (01-12-2014)“…This review of dosimetry for second cancer risk estimation introduces work carried out by Working Group 9 (WG9: Radiation Protection Dosimetry in Medicine) of…”
Get full text
Journal Article Conference Proceeding -
13
Contact radiotherapy using a 50kV X-ray system: Evaluation of relative dose distribution with the Monte Carlo code PENELOPE and comparison with measurements
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-06-2012)“…This paper presents a dosimetric study concerning the system named “Papillon 50” used in the department of radiotherapy of the Centre Antoine-Lacassagne, Nice,…”
Get full text
Journal Article -
14
Feasibility of using a dose-area product ratio as beam quality specifier for photon beams with small field sizes
Published in Physica medica (01-01-2018)“…•DAPR20,10 properties are investigated in photon beams with field sizes below 2 cm.•Influence of field size on photon spectrum and dosimetric parameters is…”
Get full text
Journal Article -
15
Monte Carlo PENRADIO software for dose calculation in medical imaging
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…The increase on the collective radiation dose due to the large number of medical imaging exams has led the medical physics community to deeply consider the…”
Get full text
Conference Proceeding -
16
Intercomparison of active personal dosemeters in interventional radiology
Published in Radiation protection dosimetry (2008)“…The use of active personal dosemeters (APD) in interventional radiology was evaluated by Working Group 9 (Radiation protection dosimetry of medical staff) of…”
Get full text
Journal Article -
17
Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
Published in Accreditation and quality assurance (01-11-2009)“…The relevant standard quantity for radiation therapy is the absorbed dose to water. This quantity refers to the amount of energy locally absorbed in a small…”
Get full text
Journal Article -
18
Some remarks on definitions and, in particular, on the definition of the term calibration
Published in Radiation protection dosimetry (01-05-2007)Get full text
Journal Article -
19
Analysis of computational problems expressing the overall uncertainties: photons, neutrons and electrons
Published in Radiation protection dosimetry (01-08-2008)“…In the frame of the EU Coordination Action CONRAD (coordinated network for radiation dosimetry), WP4 was dedicated to work on computational dosimetry with an…”
Get full text
Journal Article -
20
Contact radiotherapy using a 50 kV X-ray system: Evaluation of relative dose distribution with the Monte Carlo code PENELOPE and comparison with measurements
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-06-2012)“…This paper presents a dosimetric study concerning the system named "Papillon 50" used in the department of radiotherapy of the Centre Antoine-Lacassagne, Nice,…”
Get full text
Journal Article