Search Results - "Bojkovski, J."
-
1
The effect of Vitamin C in the therapy of haemolactia in dairy cows
Published in Journal of the Hellenic Veterinary Medical Society (21-10-2024)“…The aim of this study was to evaluate the effects of intravenous administration of vitamin C in the therapy of haemolactia in dairy cows. Haemolactia is often…”
Get full text
Journal Article -
2
Determining the Temperature Coefficient of Reference Resistors
Published in International journal of thermophysics (01-04-2017)“…The influence of temperature on electrical resistance of standard resistors is presented within this paper. Electrical resistance is like any other quantity…”
Get full text
Journal Article -
3
A numerical and experimental investigation of the heat losses in thermometric fixed-point cells
Published in International journal of heat and mass transfer (01-06-2015)“…Heat loss is one of the key parameters that cause temperature errors during the calibration of thermometers in metal-freezing-point cells and thus increases…”
Get full text
Journal Article -
4
Association between white line disease and sole ulcers with certain milk components in Simmental cows
Published in Journal of the Hellenic Veterinary Medical Society (09-07-2023)“…Lameness is one of the high influence production illnesses in intensive dairy production farming, it reduces milk yield and can also negatively affect the…”
Get full text
Journal Article -
5
Validation of Calculations in a Digital Thermometer Firmware
Published in International journal of thermophysics (2014)“…State-of-the-art digital thermometers are arguably remarkable measurement instruments, measuring outputs from resistance thermometers and/or thermocouples. Not…”
Get full text
Journal Article -
6
Comparison of the Calibration of Standard Platinum Thermometers by Comparison in the Range from -80∘C to 300∘C
Published in International journal of thermophysics (01-03-2016)“…In this paper, an interlaboratory comparison in the field of measurement of temperature is presented. Within the comparison, calibration of a standard platinum…”
Get full text
Journal Article -
7
Calibration by Comparison of Platinum Resistance Thermometers Using Slow Resistance Bridges
Published in International journal of thermophysics (01-08-2011)“…Platinum resistance thermometers (PRTs) are calibrated at the highest level in fixed points, as specified in the International Temperature Scale of 1990…”
Get full text
Journal Article -
8
Determination of PRT Hysteresis in the Temperature Range from −50 °C to 300 °C
Published in International journal of thermophysics (01-09-2010)“…This paper discusses the contribution of hysteresis to the measurement uncertainty of industrial platinum resistance thermometers (IPRTs). Hysteresis is one of…”
Get full text
Journal Article -
9
A European Roadmap for Thermometry
Published in International journal of thermophysics (2014)“…A technical roadmap for thermometry has been constructed by the EURAMET Technical Committee for Thermometry (TC-T). The roadmap first identified the key…”
Get full text
Journal Article -
10
Bilateral Comparison of Aluminum Fixed-Point Cells Using Standard Platinum Resistance Thermometer
Published in International journal of thermophysics (01-08-2011)“…The objective of Project EURAMET 1114 (Bilateral comparison of a freezing point of aluminum) in the field of thermometry is to compare realization of a…”
Get full text
Journal Article -
11
Design, Construction, and Evaluation of Ni–C Eutectic Fixed Points
Published in International journal of thermophysics (01-08-2011)“…In this article the design, construction, and evaluation of eutectic fixed points for contact and non-contact measurements that have been recently developed at…”
Get full text
Journal Article -
12
Design and validation of a new primary standard for calibration of the top-end humidity sensors
Published in Measurement : journal of the International Measurement Confederation (01-11-2008)“…The article discusses the design and results of the initial testing of a primary single pressure dew-point generator, which is used for calibration of the…”
Get full text
Journal Article -
13
Bilateral Comparison of Mercury and Gallium Fixed-Point Cells Using Standard Platinum Resistance Thermometer
Published in International journal of thermophysics (01-08-2011)“…The objective of project EURAMET 1127 (Bilateral comparison of triple point of mercury and melting point of gallium) in the field of thermometry is to compare…”
Get full text
Journal Article -
14
Investigation of resistance-ratio bridges using the automated resistance bridge calibrator
Published in Measurement : journal of the International Measurement Confederation (01-08-2009)“…The following paper analyses the methods applied in calibration of resistance bridges used in primary thermometry. The dominating contribution to uncertainties…”
Get full text
Journal Article -
15
The main indicators of biosecurity and presence of house mouse (Mus musculus L.) in animal husbandry facilities
Published in Biotechnology in animal husbandry (2014)“…Analysis of biosecurity indicators at critical control points intend to prevent undesirable infections in technological chains of production. Product quality…”
Get full text
Journal Article -
16
A Roadmap for Thermal Metrology
Published in International journal of thermophysics (01-02-2009)“…A provisional roadmap for thermal metrology was developed in Spring 2006 as part of the EUROMET iMERA activity toward increasing impact from national…”
Get full text
Journal Article -
17
Effect of Saccharomyces cerevisiae supplementation on health and performance of dairy cows during transition and early lactation period
Published in Biotechnology in animal husbandry (2015)“…Data concerning the effect of probiotics supplementation on many parameters concurrently at the same cows are lacking. Therefore, the objective of this…”
Get full text
Journal Article -
18
New Approach in Filling of Fixed-Point Cells: Case Study of the Melting Point of Gallium
Published in International journal of thermophysics (01-02-2008)“…The typical way of constructing fixed-point cells is very well described in the literature. The crucible is loaded with shot, or any other shape of pure metal,…”
Get full text
Journal Article -
19
CCT WG8 CMC Review Protocols: Development and Implementation
Published in International journal of thermophysics (01-06-2008)“…The primary objectives of the Consultative Committee on Thermometry Working Group 8 (CCT WG8) are to establish and maintain lists of service categories, to…”
Get full text
Journal Article -
20
Colostrum composition before and after calving in Holstein-Friesian cows
Published in Veterinary record (04-06-2005)Get full text
Journal Article