Search Results - "Boenick, U."

Refine Results
  1. 1

    Influence of different trocar tips on abdominal wall penetration during laparoscopy by BÖHM, B, KNIGGE, M, KRAFT, M, GRÜNDEL, K, BOENICK, U

    Published in Surgical endoscopy (01-12-1998)
    “…Most trocars currently used to place a cannula through the abdominal wall have a conical or pyramidal tip. Because the risk of inadvertent injury along with…”
    Get full text
    Journal Article
  2. 2

    Ultrasonic surfactant nebulization with different exciting frequencies by Wagner, M.H, Wiethoff, S, Friedrich, W, Mollenhauer, I, Obladen, M, Boenick, U

    Published in Biophysical chemistry (14-02-2000)
    “…Intratracheal bolus instillation of natural lung surfactant is the treatment of choice in neonatal respiratory distress syndrome and an increasing part in…”
    Get full text
    Journal Article
  3. 3

    The effects of the use of piezoelectric motors in a 1.5-Tesla high-field magnetic resonance imaging system (MRI) by Wendt, O, Oellinger, J, Lüth, T C, Felix, R, Boenick, U

    Published in Biomedizinische Technik (01-01-2000)
    “…This paper presents the results of an experimental investigation with two different rotatory piezomotors in a closed 1.5 Tesla high-field MRI. The focus of the…”
    Get more information
    Journal Article
  4. 4
  5. 5

    A novel method for patient-oriented assignment of wheelchair cushions based on standardized laboratory testing procedures by Diesing, P, Hochmann, D, Boenick, U, Kraft, M

    Published in Biomedizinische Technik (01-06-2005)
    “…A wheelchair seat cushion represents the interface between the wheelchair and the wheelchair driver and has to manage the force transmission and the…”
    Get more information
    Journal Article
  6. 6

    Drive principles of a triaxial physiological hip joint simulator for wear testing of hip endoprostheses by Springstein, D, Wendt, Z, Boenick, U

    Published in Biomedizinische Technik (01-04-2003)
    “…The long-term performance of hip joint replacements is a major criterion for quality assessment. Aseptic loosening as a result of wear has a considerable…”
    Get more information
    Journal Article
  7. 7
  8. 8
  9. 9
  10. 10
  11. 11

    Evaluation of measurement systems for determining therapeutic effectiveness of anti-decubitus ulcer devices by Hochmann, D, Diesing, P, Boenick, U

    Published in Biomedizinische Technik (2002)
    “…Interface pressure measurement is today a most used technique for laboratory evaluation of support surfaces in prevention of pressure sores. This article…”
    Get more information
    Journal Article
  12. 12

    Possibilities for optimizing prosthetic management of leg amputees using quantitative movement analysis by Boenick, U

    Published in Biomedizinische Technik (01-06-1993)
    “…First, the differences between natural and artificial lower extremities are discussed from a biomechanical perspective. Their effects on the motion can be…”
    Get more information
    Journal Article
  13. 13

    Personal emergency call system based on human vital and system technical parameters in a Smart Home environment by Hampicke, M, Schadow, B, Rossdeutscher, W, Fellbaum, K, Boenick, U

    Published in Biomedizinische Technik (01-11-2002)
    “…Progress in microtechnology and radio transmission technology has enabled the development of highly reliable emergency-call systems. The present article…”
    Get more information
    Journal Article
  14. 14

    Modeling vestibulo-ocular reflexes in everyday activities by Ossig, J, Boenick, U

    Published in Biomedizinische Technik (01-05-1996)
    “…Fundamental data for the establishment of a new clinical testing procedure for patients suffering from equilibrium disorders were developed. A mathematical…”
    Get more information
    Journal Article
  15. 15
  16. 16

    Integrated gait analysis for future routine clinical use by Mainka, C, Boenick, U

    Published in Biomedizinische Technik (01-12-1993)
    “…To describe the phenomenon of human movement by means of kinematic and kinetic measurements in a more objective manner, so-called integrated gait analysis…”
    Get more information
    Journal Article
  17. 17

    Possibilities for recognizing and suppressing artifacts in EMG signals by Kitzenmaier, P, Boenick, U

    Published in Biomedizinische Technik (01-09-1993)
    “…Two methods are introduced to suppress artifacts in the EMG signal, as can occur with EMG detection. These methods are based upon an adaptive threshold, which…”
    Get more information
    Journal Article
  18. 18

    Kinetic and kinematic gait analysis before and after total knee endoprosthesis implantation by Perka, C, Möckel, G, Boenick, U

    “…The aim of the present paper was to make an objective assessment of the surgical outcome after primary knee endoprosthesis implantation by means of gait…”
    Get more information
    Journal Article
  19. 19

    Multifunctional testing of PTCA balloon catheters by Kraft, M, Schmitz, H, Schulte, R, Boenick, U

    Published in Biomedizinische Technik (01-06-2000)
    “…New in vitro measuring methods for balloon catheters used for percutaneous transluminal coronary angioplasty (PTCA) and their verification in a complex test…”
    Get more information
    Journal Article
  20. 20