Search Results - "Bjursten, L.M"
-
1
A Novel Cell Force Sensor for Quantification of Traction during Cell Spreading and Contact Guidance
Published in Biophysical journal (01-07-2007)“…In this work, we present a ridged, microfabricated, force sensor that can be used to investigate mechanical interactions between cells exhibiting contact…”
Get full text
Journal Article -
2
Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium
Published in IEEE transactions on biomedical engineering (01-04-2002)“…Square-shaped silicon or titanium implants with plane or porous surfaces surrounded by a rim of silicone were implanted in the rat abdominal wall for…”
Get full text
Journal Article -
3
COX-2 is necessary for venous ligation-mediated bone adaptation in mice
Published in Bone (New York, N.Y.) (2006)“…In osteoblasts, cyclooxygenase 2 (COX-2) is the major isozyme responsible for production of prostaglandins. Prostaglandins are local mediators of bone…”
Get full text
Journal Article -
4
Tissue response to commercial silicone and polyurethane elastomers after different sterilization procedures
Published in Biomaterials (01-12-1996)“…Two different commercial polymeric materials, a silicone and a polyurethane (PUR), were studied with regard to correlations between the chemical and physical…”
Get full text
Journal Article -
5
Nerve regeneration in a `pseudo-nerve' graft created in a silicone tube
Published in Brain research (19-09-1997)“…The pseudo-nerve, which contains longitudinal Schwann cell columns without axons and surrounded by perineurium-like tissue but no axons (Q. Zhao, L.B. Dahlin,…”
Get full text
Journal Article -
6
Immunohistochemical study of the soft tissue around long-term skinpenetrating titanium implants
Published in Biomaterials (1995)“…Bone-anchored percutaneous titanium implants have become a well-established clinical procedure with a low incidence of adverse reactions. However, passage…”
Get full text
Journal Article -
7
Tissue Reactions to Porous Silicon: A Comparative Biomaterial Study
Published in Physica status solidi. A, Applied research (01-11-2000)“…This study addresses cellular reactions in soft tissue induced by implants of porous and planar silicon, oxidised (porous) titanium and polished (planar)…”
Get full text
Journal Article -
8
Method for ultrastructural studies of the intact tissue-metal interface
Published in Biomaterials (01-10-1990)“…Samples were prepared for ultrastructural studies of the intact interface between metallic implants and tissue by transmission electron microscopy. The method…”
Get more information
Journal Article -
9
Optimized density gradient separation of leukocyte fractions from whole blood by adjustment of osmolarity
Published in Journal of immunological methods (06-11-1986)“…Some of the compounds used for density gradient separation of blood cells have high osmolarities at the concentrations needed to create the required specific…”
Get more information
Journal Article -
10
Hollow implants in soft tissues allowing quantitative studies of cells and fluid at the implant interface
Published in Biomaterials (01-01-1988)“…In order to study the early cellular response in the fluid phase found close to implants in soft tissues, an experimental method using a hollow implant was…”
Get more information
Journal Article -
11
Migration of human granulocytes in filters: effects of gravity and movable gradients of f-MLP
Published in Biorheology (Oxford) (01-11-1994)“…The Boyden chamber technique for chemotaxis uses a mesh filter that constitutes a matrix for cell locomotion and, at the same time, creates a local restriction…”
Get more information
Journal Article -
12
Detection of blood group type glycosphingolipid antigens on thin-layer plates using polyclonal antisera
Published in Journal of immunological methods (24-10-1985)“…The conditions for binding of antibodies to glycosphingolipids separated on a thin-layer plate have been optimized for polyclonal antisera. The method has a…”
Get more information
Journal Article -
13
Cell necrosis, capsule formation, and soft tissue response to implants
Published in Proceedings of the First Joint BMES/EMBS Conference : serving humanity advancing technology, Oct. 13-16, 99, Atlanta, GA, USA (1999)“…The tissue response to implanted polyethylene discs was evaluated. Cells with increased membrane permeability could be identified using fluorescence microscopy…”
Get full text
Conference Proceeding Journal Article -
14
Perforated silicon membranes as an artificial neural contact pad-chip design and tissue implant response
Published in Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (1996)“…Silicon membranes (diameter=4 mm, thickness=60 /spl mu/m) with a circular matrix of holes centered at the chip were fabricated using anisotropic etching. The…”
Get full text
Conference Proceeding -
15
Joint inflammation in rabbits induced by preformed immune complexes
Published in International archives of allergy and applied immunology (1981)“…The rabbit knee joint was used to evaluate the inflammatory properties of immune complexes with different contents of antigen. Immune complexes made in vitro…”
Get more information
Journal Article -
16
Spot immunoprecipitate assay in gel compared with immune reactions in solution and applied to antibody titration
Published in Journal of immunological methods (26-08-1983)“…Precipitation profiles of spot immunoprecipitate assay (SIA) reactions in gel are shown to have characteristics analogous to classic precipitin curves…”
Get more information
Journal Article -
17
Evaluation of circulating immune complex-like material for development of skin reactions in connection with penicillin therapy
Published in International archives of allergy and applied immunology (01-01-1981)“…The levels of immune complex-like material in serum from 18 patients in connection with skin eruptions appearing during penicillin therapy were determined with…”
Get more information
Journal Article