An Analysis of Blood Management in Patients Having a Total Hip or Knee Arthroplasty
Published in Journal of bone and joint surgery. American volume (01-01-1999)“…Three hundred and thirty orthopaedic surgeons in the United States participated in a study of transfusion requirements associated with total joint…”
Get full text
Journal Article -
2
Effect of low-friction ion-treated femoral heads on polyethylene wear rates
Published in Clinical orthopaedics and related research (01-01-2000)“…Polyethylene wear is a major contributor to osteolysis and subsequent aseptic loosening of prosthetic components in total hip arthroplasty. Use of ion…”
Get more information
Journal Article -
3
Blood conservation in total joint arthroplasty
Published in Orthopedics (Thorofare) (01-09-1998)Get full text
Conference Proceeding Journal Article -
4
Autologous blood donation and subsequent blood use in patients undergoing total knee arthroplasty
Published in Transfusion medicine (Oxford, England) (01-10-2006)“…summary Autologous blood donation is designed to avoid complications from allogeneic blood, leaving units of blood in the general blood supply. It is unclear…”
Get full text
Journal Article -
5
Dual proline labeling protocol for individual “baseline” and “response” biosynthesis measurements in human articular cartilage
Published in Osteoarthritis and cartilage (01-10-2008)“…Summary Objective The heterogeneity of biosynthesis in human-derived cartilage explants poses a challenge to its use in experiments. The aim of this study was…”
Get full text
Journal Article -
6
Role of cell-matrix interactions in osteoclast differentiation
Published in Advances in experimental medicine and biology (2007)“…Osteoclast and their mononuclear cell precursors are present within the bone microenvironment at sites of physiologic and pathologic bone resorption. Analysis…”
Get more information
Journal Article -
7
Bone scanning in the assessment of patellar viability following knee replacement
Published in Clinical orthopaedics and related research (01-10-1985)“…In an attempt to diagnose avascular necrosis (AVN) of the patella, a potential complication of the surgical procedure, 99mTc-MDP bone scanning was performed…”
Get more information
Journal Article -
8
Transmission electron microscopy of intracellular particles of polyethylene from joint replacement prostheses: size distribution and cellular response
Published in Biomaterials (01-11-2001)“…The objectives of this transmission electron microscopy study of peri-implant tissues retrieved at revision arthroplasty were to (1) determine the size…”
Get full text
Journal Article -
9
Complications of resurfacing arthroplasty
Published in The Orthopedic clinics of North America (01-10-1982)Get more information
Journal Article -
10
Particulate bone grafting of osteolytic femoral lesions around stable cementless stems
Published in Clinical orthopaedics and related research (01-12-2000)“…The purpose of the current study was to evaluate the effect of particulate grafting for proximal femoral osteolysis in the presence of a well-fixed cementless…”
Get more information
Journal Article -
11
Hydroxyapatite coating on the femoral stem in primary total hip arthroplasty
Published in Orthopedics (Thorofare, N.J.) (01-09-2003)“…Since the mid 1980s, hydroxyapatite coating on femoral implants has been used to enhance bone attachment to the implant surface. Porous or mesh coating…”
Get full text
Journal Article -
12
Trochanteric osteotomy: analysis of pattern of wire fixation failure and complications
Published in Clinical orthopaedics and related research (01-01-1979)“…Problems and complications following trochanteric osteotomy in 277 total hip replacements demonstrated that while the value of trochanteric osteotomy is…”
Get more information
Journal Article -
13
Hip arthroplasties in Gaucherʼs disease
Published in Journal of bone and joint surgery. American volume (01-04-1981)“…In six patients with Gaucherʼs disease, arthroplasties were performed on ten hips for avascular necrosis of the femoral head. The follow-up ranged from two to…”
Get full text
Journal Article -
14
Removal and reinsertion of cemented femoral components during acetabular revision
Published in The Journal of arthroplasty (01-02-1996)“…A retrospective review examined all patients who underwent removal and reinsertion of a cemented femoral component during isolated acetabular revision by one…”
Get full text
Journal Article -
15
Ceramic-on-ceramic hip outcome at a 5- to 10-year interval: has it lived up to its expectations?
Published in The Journal of arthroplasty (01-02-2011)“…This study reports revision and complication rates of a single cementless double-wedged tapered stem with an alumina-alumina bearing over 10 years since the…”
Get full text
Journal Article -
16
Modified non-clogging suction apparatus
Published in Clinical orthopaedics and related research (01-03-1981)Get more information
Journal Article -
17
Axial debridement for femoral stem placement
Published in Clinical orthopaedics and related research (01-03-1981)Get more information
Journal Article -
18
Hip challenges : What would you do?
Published in Orthopedics (Thorofare) (01-09-1998)Get full text
Conference Proceeding Journal Article -
19
Surgical considerations and planning for acetabular and femoral deficiencies in revision hip replacement
Published in Bulletin of the Hospital for Joint Diseases Orthopaedic Institute (1989)“…Cementless revision total hip arthroplasty provides a method for augmenting and restoring the remaining bone stock in a failed total hip arthroplasty. Careful…”
Get more information
Journal Article -
20
Intermediate clinical follow-up of a dual-radius acetabular component
Published in The Journal of arthroplasty (01-10-1998)“…In this study, 92 primary total hip arthroplasties were performed in 83 patients using a porous-coated, dual-radius, cementless, acetabular component. All hips…”
Get full text
Journal Article