Search Results - "Benenson, D M"
-
1
Event timing and shape analysis of vibration bursts from power circuit breakers
Published in IEEE transactions on power delivery (01-04-1996)“…Noninvasive vibration diagnostic techniques are implemented to assess the mechanical condition of power circuit breakers. A diagnostic system, the prototype…”
Get full text
Journal Article Conference Proceeding -
2
A noninvasive diagnostic instrument for power circuit breakers
Published in IEEE transactions on power delivery (01-04-1992)“…Noninvasive diagnostics, involving short-time spectra, short-time energy, and automatic timing techniques, have been applied to assess the mechanical condition…”
Get full text
Journal Article Conference Proceeding -
3
Noninvasive condition assessment and event timing for power circuit breakers
Published in IEEE transactions on power delivery (01-01-1992)“…Noninvasive diagnostics, involving short-time spectra, short-time energy, and automatic timing techniques, were used to assess the mechanical condition of oil…”
Get full text
Journal Article Conference Proceeding -
4
Mechanical failure detection of circuit breakers
Published in IEEE transactions on power delivery (01-10-1988)“…The mechanical condition of a circuit breaker, i.e., whether the unit is in normal or abnormal condition, has been evaluated using noninvasive diagnostics,…”
Get full text
Journal Article Conference Proceeding -
5
Arc Mantle Studies in Dual Flow Plasmas
Published in IEEE transactions on plasma science (01-08-1986)“…Differential interferometry, using the Wollaston prism, has been applied in the upstream and downstream regions of a dual flow orifice nozzle interrupter. The…”
Get full text
Journal Article -
6
Temperature Diagnostics in Turbulent Arcs
Published in IEEE transactions on plasma science (01-01-1980)“…Time averaged radial distributions of temperature and its fluctuations have been obtained for turbulent (and laminar) dc-argon arcs operated at 65 A in a 1-cm…”
Get full text
Journal Article -
7
Study of deposition offset in plasma spray of zirconia
Published in Plasma chemistry and plasma processing (01-03-1996)“…Numerical modeling and experimental measurements have been performed to study the effects of powder carrier gas flow rates and powder sizes on the deposition…”
Get full text
Journal Article -
8
Risk behaviour and time as covariates for efficacy of the HIV vaccine regimen ALVAC-HIV (vCP1521) and AIDSVAX B/E: a post-hoc analysis of the Thai phase 3 efficacy trial RV 144
Published in The Lancet infectious diseases (01-07-2012)“…Summary Background The Thai phase 3 HIV vaccine trial RV 144 showed modest efficacy of a vaccine against HIV acquisition. Baseline variables of age, sex,…”
Get full text
Journal Article -
9
Numerical Analysis of Alternating Current Arcs
Published in IEEE transactions on plasma science (01-12-1974)“…Solutions of the coupled, nonlinear, two-dimensional, non-steady equations of continuity, momentum, and energy have been obtained for an alternating current…”
Get full text
Journal Article -
10
The Thermal Boundary Layer in Dual Flow Arc Plasmas
Published in IEEE transactions on plasma science (01-12-1984)“…Differential interferometry techniques (using the Wollaston prism) have been applied to a dynamic plasma to determine the radial and temporal distributions of…”
Get full text
Journal Article -
11
Turbulence in alternating current arcs
Published in Proceedings of the IEEE (01-01-1976)“…Spectroscopic measurements of the integrated intensity distributions of the radiation from turbulent ac plasmas have two sources for the appearance of…”
Get full text
Journal Article -
12
Temperature Measurements in Alternating Current Cross-Flow Arcs
Published in IEEE transactions on plasma science (01-01-1977)“…Using optical techniques appropriate to columns having non-circular cross-section, temperature distributions within an alternating current cross-flow arc…”
Get full text
Journal Article -
13
-
14
Use of the Nonwire Central Line Hub to Reduce Blood Culture Contamination
Published in Chest (01-03-2013)“…Background The sterile conditions used when inserting a central venous catheter (CVC) might be thought to decrease the contamination rate of blood cultures…”
Get full text
Journal Article -
15
A Crew Resource Management Program Tailored to Trauma Resuscitation Improves Team Behavior and Communication
Published in Journal of the American College of Surgeons (01-09-2014)“…Background Crew Resource Management (CRM) is a team-building communication process first implemented in the aviation industry to improve safety. It has been…”
Get full text
Journal Article -
16
Study of deposition offset in plasma spray of zirconia
Published in Plasma chemistry and plasma processing (01-03-1995)Get full text
Journal Article -
17
Factors Influencing Work–Life Balance in Physicians and Advance Practice Clinicians and the Effect of Heartfulness Meditation Conference on Burnout
Published in Global advances in health and medicine (01-01-2019)“…Background Burnout levels have risen in recent years and satisfaction with work–life balance has decreased. Individual and organizational factors may affect…”
Get full text
Journal Article -
18
Application of San Francisco Syncope Rule in elderly ED patients
Published in The American journal of emergency medicine (01-09-2008)“…Abstract Objectives The San Francisco Syncope Rule (SFSR) is a decision rule with the potential to identify patients at risk for serious outcomes within 7 days…”
Get full text
Journal Article -
19
Simulations And Measurements Of Alumina Particles In Plasma Spraying
Published in Proceedings of 1994 IEEE 21st International Conference on Plasma Sciences (ICOPS) (1994)Get full text
Conference Proceeding