Search Results - "Bellunato, T"
-
1
Refractive index of silica aerogel: Uniformity and dispersion law
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2008)“…Two methods for the measurement of the uniformity of the refractive index n within a single block of silica aerogel are described. One is based on the…”
Get full text
Journal Article -
2
Refractive index dispersion law of silica aerogel
Published in The European physical journal. C, Particles and fields (01-11-2007)“…This paper presents measurements of the refractive index of a hygroscopic silica aerogel block at several wavelengths. The measurements, performed with a…”
Get full text
Journal Article -
3
VUV absorbing vapours in n-perfluorocarbons
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-09-2003)“…The optical transparency of perfluorocarbons used as Cherenkov media is of prime importance to many Ring Imaging Cherenkov detectors. We will in this paper…”
Get full text
Journal Article -
4
Proximity focusing RICH detector based on multilayer silica aerogel radiator
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-05-2010)“…The performance of a proximity focusing Ring Imaging Cherenkov detector equipped with a radiator of silica aerogel is presented. The aerogel tile used is a…”
Get full text
Journal Article -
5
The High Voltage Protection Boards for the RICH Detectors of the LHCb Experiment
Published in IEEE transactions on nuclear science (01-10-2009)“…We present the protection system for the monitoring circuitry of the 20 kV high-voltage bias for the Hybrid Photon Detectors of the Ring Imaging Cherenkov…”
Get full text
Journal Article -
6
Refractive index inhomogeneity within an aerogel block
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (2006)“…Evaluating local inhomogeneities of the refractive index inside aerogel blocks to be used as Cherenkov radiator is important for a high energy physics…”
Get full text
Journal Article -
7
Study of ageing effects in aerogel
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-07-2004)“…Ageing effects on aerogel due to irradiation and absorption of humidity have been investigated. Aerogel tiles have been exposed to γ radiation from a 60 Co…”
Get full text
Journal Article -
8
The high voltage distribution system for the hybrid photodetector arrays of RICH1 and RICH2 at LHCb
Published in IEEE transactions on nuclear science (01-06-2006)“…Two Ring Imaging CHerenkov detectors, RICH1 and RICH2, will provide the particle identification of the LHCb experiment. The Cherenkov light cones produced in…”
Get full text
Journal Article -
9
The radiator gas and the gas system of COMPASS RICH-1
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-04-2003)“…The design of the COMPASS RICH-1 gas system, its operational modes, the cleaning setups for the preparation of the radiator gas and transmission measurement…”
Get full text
Journal Article -
10
First performances of COMPASS RICH-1
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2004)“…COMPASS RICH-1, designed in 1996 for hadron identification at high momenta in the COMPASS large angle spectrometer, is based on the use of MWPCs with large…”
Get full text
Journal Article -
11
Performance of the LHCb RICH photo-detectors and readout in a system test using charged particles from a 25 ns-structured beam
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-05-2009)“…The LHCb experiment at the CERN Large Hadron Collider (LHC) utilises two Ring Imaging CHerenkov (RICH) detectors for particle identification. To verify that…”
Get full text
Journal Article -
12
Light composite mirrors for RICH detectors: production, characterisation and stability tests
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-02-2005)“…The production of lightweight composite mirror prototypes suitable for application in Ring Imaging Cherenkov (RICH) detectors is described. The goal is the use…”
Get full text
Journal Article -
13
Development of aerogel Cherenkov detectors at Novosibirsk
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-11-2005)“…The development of aerogel Cherenkov counters with the light collection using a wavelength shifter is described. 80 counters of this type are working in the…”
Get full text
Journal Article -
14
Performance of aerogel as Cherenkov radiator
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-03-2004)“…Aerogel with index of refraction around 1.03 has been studied as Cherenkov radiator in a test at CERN PS using a π − and a mixed π +/p beam of momenta between…”
Get full text
Journal Article -
15
The RICH detector of the LHCb experiment
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (2009)“…The status of the Ring Imaging Cherenkov system of the LHCb experiment is reviewed. The detector is in the commissioning phase and it is expected to take data…”
Get full text
Journal Article -
16
Cherenkov rings from aerogel detected by four large-area hybrid photodiodes
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-05-2003)“…We report on the results obtained using thick samples of silica aerogel as radiators for a Ring Imaging Cherenkov counter. Four large-diameter hybrid…”
Get full text
Journal Article -
17
Aerogel as Cherenkov radiator for RICH detectors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-04-2003)“…We present here the results obtained using silica aerogel as Cherenkov radiator for the separation and identification of particles in the momentum range from 6…”
Get full text
Journal Article -
18
Development of aerogel Cherenkov counters at Novosibirsk
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-08-2006)“…The work on aerogel Cherenkov counters was started in Novosibirsk in 1986. Production of aerogels with refractive indices of 1.006–1.13 and thicknesses of…”
Get full text
Journal Article -
19
Testbeam results on particle identification with aerogel used as RICH radiator
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2002)“…We present the results obtained by testing in a beam sample of silica aerogel which is foreseen as one of the radiators for the Ring Imaging Cherenkov counter…”
Get full text
Journal Article -
20
Testbeam results on particle identification with aerogel used as RICH radiator
Published in IEEE transactions on nuclear science (01-08-2001)“…We present the results obtained by exposing samples of silica aerogel of different thickness and optical properties to pion and proton beams with momenta…”
Get full text
Journal Article