Search Results - "Belavskaya, S. V."

Refine Results
  1. 1

    Plots of electric field strength in biological tissue irradiated with slot type MW irradiator by Belavskaya, S.V., Lisitsyna, L.I., Alekseev, S.V.

    “…The electric field caused by a slot type MW irradiator is pictured and analyzed. It is shown that in the direction normal to the slot irradiator the electric…”
    Get full text
    Conference Proceeding
  2. 2

    Experimental research on ultrasonic vibration intensity distribution in biological tissue under treatment with insonator for inner cavities by Belavskaya, S.V., Knyazeva, I.A., Lisitsyna, L.L.

    “…The results of the research on ultrasonic vibration intensity distribution in biological tissue under treatment with an inner cavities insonator made of a…”
    Get full text
    Conference Proceeding
  3. 3
  4. 4
  5. 5

    MW electromagnetic field distribution in biological tissue under slot irradiator treatment by Belavskaya, S.V., Lisitsyna, L.I., Plavsky, L.G., Alekseev, S.V.

    “…The electromagnetic field distributions calculated and obtained in the experiments on biological tissues are analyzed. A close agreement between calculated and…”
    Get full text
    Conference Proceeding
  6. 6

    Distribution of magnetic field in biological tissue under intracavity treatment by small-size inductor by Belavskaya, S.V., Domashenko, R.S., Lisitsyna, L.I., Temnov, D.N., Novikova, E.N., Elkin, M.V.

    “…Experimental results and calculations of the distribution of a magnetic field in biological tissue under intracavity treatment by a small-size inductor are…”
    Get full text
    Conference Proceeding
  7. 7

    Ultrasonic insonator for reflexotherapy by Adoniev, V.G., Belavskaya, S.V., Grechin, E.A., Dobrova, O.I., Lisitsyna, L.I.

    “…Ultrasonic insonator (USI) consisting of piezoceramic plate with rigidly connected steel rod is considered. A method for acoustic signal intensity calculation…”
    Get full text
    Conference Proceeding
  8. 8

    Analysis of experimental and numerical calculations results on microwave irradiator for reflexotherapy by Belavskaya, S.V., Berezhinskii, I.V., Vityugov, V.A., Lisitsyna, L.I., Shebalkova, L.V.

    “…Experimental results as well as calculations on the microwave irradiator for reflexotherapy made of piece of coaxial waveguide are discussed. The calculations…”
    Get full text
    Conference Proceeding
  9. 9

    MW energy irradiator for reflexotherapy by Belavskaya, S.V., Berezhinskii, I.V., Vityugov, V.A., Lisitsyna, L.I., Likhanov, Y.M.

    “…The efficiency of MW power transmission from the end of a coaxial waveguide to a biologically active point (BAP) is considered. The distribution of the power…”
    Get full text
    Conference Proceeding
  10. 10

    Choice of scanning signal working frequency for skin surface sponginess estimation using ultrasonic vibrations by Belavskaya, S. V., Kuzmin, A. N., Lisitsyna, L. I., Navrotsky, L. G., Pedder, V. V.

    “…The research on the choice of scanning signal working frequency for skin surface sponginess estimation using ultrasonic vibrations has been made. The…”
    Get full text
    Conference Proceeding
  11. 11

    Research on possibility of visualization of biologically active points by light illumination by Navrotsky, L. G., Lisitsyna, L. I., Yudin, V. I., Belavskaya, S. V., Blokhin, A. A., Rusetsky, V. S.

    “…Results of preliminary experiments on the possibility of biologically active points (BAP) visualization by illuminating them with light pulse causing…”
    Get full text
    Conference Proceeding
  12. 12

    Dependence of influence of contrast temperature on electrical resistance of the small area integument by Belavskaya, S V, Verzilin, S A, Gavrilov, E A, Lisitsyna, L I, Pedonova, Z N

    “…Primary results of researches of influence of contrast temperature influences on electric resistance of the small area integument are presented. Normalized…”
    Get full text
    Conference Proceeding
  13. 13

    Distribution of Electrical Field Over the Lateral Surface of MW Irradiator for Intracavitary Treatment by Belavskaya, S.V., Lisitsyna, L.I., Rodionov, A.S.

    “…Distribution of electrical field over the lateral surface of MW irradiator for intracavitary treatment is considered. The irradiator consists of parallel slots…”
    Get full text
    Conference Proceeding
  14. 14

    Research on the Possibility for Reflexotherapy MW Irradiator to Increase MW Electromagnetic Oscillations Penetration Depth into Biological Tissue by Belavskaya, S.V., Koltkov, D.S., Lisitsyna, L.I.

    “…The results of calculations of MW electromagnetic (EM) oscillations penetration depth into biological tissue (BT) under treatment by MW irradiator for…”
    Get full text
    Conference Proceeding
  15. 15

    Sectional Ultrasonic Irradiator for Intracavitary Treatment by Belavskaya, S.V., Kuchma, I.A., Lisitsyna, L.I., Adonev, V.G., Firsova, K.F.

    “…In this paper experimental results on sectional ultrasonic irradiator (USI), which is implemented on several piezoplates located parallel to each other on…”
    Get full text
    Conference Proceeding
  16. 16
  17. 17

    Complex MW and ultrasonic irradiator for reflexotherapy by Belavskaya, S.V., Berezhynskii, I.V., Bogatkina, O.I., Vekhovantes, A.A., Lisitsyna, L.I.

    “…Complex irradiator for reflexotherapy capable of time and spatial superposition of MW and ultrasonic (US) irradiation of biologically active points (BAF)…”
    Get full text
    Conference Proceeding
  18. 18
  19. 19
  20. 20

    Improvement of magnetic induction distribution uniformity along lateral surface of small-size inductor by Belavskaya, S.V., Domashenko, R.S., Lisitsyna, L.I.

    “…Results of the research on various designs of small-size inductor for intracavitary treatment are considered. Its revealed that use of noncontinuous specified…”
    Get full text
    Conference Proceeding