Search Results - "Baumert, Mark"
-
1
Proteomics Characterization of Extracellular Space Components in the Human Aorta
Published in Molecular & cellular proteomics (01-09-2010)“…The vascular extracellular matrix (ECM) is essential for the structural integrity of the vessel wall and also serves as a substrate for the binding and…”
Get full text
Journal Article -
2
Localization of sterols and oxysterols in mouse brain reveals distinct spatial cholesterol metabolism
Published in Proceedings of the National Academy of Sciences - PNAS (17-03-2020)“…Dysregulated cholesterol metabolism is implicated in a number of neurological disorders. Many sterols, including cholesterol and its precursors and…”
Get full text
Journal Article -
3
Shotgun lipidomics on a LTQ Orbitrap mass spectrometer by successive switching between acquisition polarity modes
Published in Journal of mass spectrometry. (01-01-2012)“…Top–down shotgun lipidomics relies on direct infusion of total lipid extracts into a high‐resolution tandem mass spectrometer and implies that individual…”
Get full text
Journal Article -
4
Integration of Ion Mobility MSE after Fully Automated, Online, High-Resolution Liquid Extraction Surface Analysis Micro-Liquid Chromatography
Published in Analytical chemistry (Washington) (17-10-2017)“…Direct analysis by mass spectrometry (imaging) has become increasingly deployed in preclinical and clinical research due to its rapid and accurate readouts…”
Get full text
Journal Article -
5
Comparative Lipidomics Profiling of Human Atherosclerotic Plaques
Published in Circulation. Cardiovascular genetics (01-06-2011)“…BACKGROUND—We sought to perform a systematic lipid analysis of atherosclerotic plaques using emerging mass spectrometry techniques. METHODS AND RESULTS—A…”
Get full text
Journal Article -
6
Using a single, high mass resolution mass spectrometry platform to investigate ion suppression effects observed during tissue imaging
Published in Rapid communications in mass spectrometry (15-05-2014)“…RATIONALE The signal intensity of a given molecule across a tissue section when measured using mass spectrometry imaging (MSI) is prone to changes caused by…”
Get full text
Journal Article -
7
Rapid profiling of triglycerides in human breast milk using liquid extraction surface analysis Fourier transform mass spectrometry reveals new very long chain fatty acids and differences within individuals
Published in Rapid communications in mass spectrometry (15-08-2019)“…Rationale We describe a novel method for preparing milk samples and profiling their triglyceride (TG) fractions. This method was used to explore how the TG…”
Get full text
Journal Article -
8
Hemoglobin Variant Analysis via Direct Surface Sampling of Dried Blood Spots Coupled with High-Resolution Mass Spectrometry
Published in Analytical chemistry (Washington) (15-03-2011)“…Hemoglobinopathies are the most common inherited disorders. Newborn blood screening for clinically significant hemoglobin variants, including sickle (HbS),…”
Get full text
Journal Article -
9
Integration of Ion Mobility MS E after Fully Automated, Online, High-Resolution Liquid Extraction Surface Analysis Micro-Liquid Chromatography
Published in Analytical chemistry (Washington) (17-10-2017)“…Direct analysis by mass spectrometry (imaging) has become increasingly deployed in preclinical and clinical research due to its rapid and accurate readouts…”
Get full text
Journal Article -
10
Correlation of Skin Blanching and Percutaneous Absorption for Glucocorticoid Receptor Agonists by Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging and Liquid Extraction Surface Analysis with Nanoelectrospray Ionization Mass Spectrometry
Published in Analytical chemistry (Washington) (15-09-2010)“…Matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) and liquid extraction surface analysis (LESA) with nanoelectrospray…”
Get full text
Journal Article -
11
Application of the Exactive Plus EMR for automated protein-ligand screening by non-covalent mass spectrometry
Published in Rapid communications in mass spectrometry (15-07-2014)“…RATIONALE Non‐covalent mass spectrometry (MS) offers considerable potential for protein‐ligand screening in drug discovery programmes. However, there are some…”
Get full text
Journal Article -
12
Simultaneous selected reaction monitoring, MS/MS and MS3 quantitation for the analysis of pharmaceutical compounds in human plasma using chip-based infusion
Published in Rapid communications in mass spectrometry (01-01-2004)“…An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human…”
Get full text
Journal Article -
13
Use of a Microchip Device Coupled with Mass Spectrometry for Ligand Screening of a Multi-Protein Target
Published in Analytical chemistry (Washington) (15-09-2003)“…Nanoflow electrospray mass spectrometry has been applied previously to investigate noncovalent protein−protein and protein−ligand interactions. Here we…”
Get full text
Journal Article -
14
Simultaneous selected reaction monitoring, MS/MS and MS 3 quantitation for the analysis of pharmaceutical compounds in human plasma using chip‐based infusion
Published in Rapid communications in mass spectrometry (15-09-2004)“…An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human…”
Get full text
Journal Article