Search Results - "Barabash, L.I."
-
1
Radiation hardness of silicon detectors based on pre-irradiated silicon
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (30-11-2006)“…Radiation hardness of planar detectors processed from pre-irradiated and thermo-annealed n-type FZ silicon substrates, and standard FZ as a reference, was…”
Get full text
Journal Article -
2
Semiconductor detectors for neutron flux measurements
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2004)“…Silicon detectors with 235U converter for neutron flux measurements over a wide energy range (from thermal up to epithemal neutrons) have been developed. The…”
Get full text
Journal Article -
3
Silicon detectors for γ-ray and β-spectroscopy
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-10-2003)“…Large active volume Si(Li) detectors were successfully developed for γ-ray spectrometry at room temperature that show a sufficient efficiency and an energy…”
Get full text
Journal Article -
4
Study of neutron pre-irradiated silicon for nuclear detectors
Published in IEEE Symposium Conference Record Nuclear Science 2004 (2004)“…The ways of increasing the radiation hardness of silicon were considered. It was then experimentally shown that a preliminary irradiation of the bulk silicon…”
Get full text
Conference Proceeding -
5
P-Channel MOS Sensor for Measurement of Emergency Gamma and Neutron Irradiation
Published in Radiation protection dosimetry (01-07-1996)“…A dosemeter for mixed gamma-neutron fields using p-MOSDET with thick oxide has been designed and studied. A positive charge is stored in the gate oxide under…”
Get full text
Journal Article Conference Proceeding -
6
Strip detector for short-range particles
Published in IEEE transactions on nuclear science (01-08-1992)“…A silicon strip detector for the coordinate determination of short-range charged particles, particularly heavy ions, has been developed. The detector has 28…”
Get full text
Journal Article Conference Proceeding -
7
Ten channel background alpha radiometer for nondestructive analysis of low activity samples
Published in IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) (01-10-1992)“…A ten-channel alpha-radiometer based on large-area semiconductor detectors is presented. The radiometer is intended for determination of soil pollution by…”
Get full text
Journal Article Conference Proceeding -
8
Ten channel low background alpha radiometer for nondestructive analysis of low activity samples
Published in Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference (1991)“…A description of a 10-channel alpha-radiometer with large-area semiconductor detectors is presented. The radiometer is designed for the determination of soil…”
Get full text
Conference Proceeding -
9
Strip detector for short-range particles
Published in Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference (1991)“…A silicon strip detector for the coordinate determination of the short-range charged particles, particularly heavy ions, has been developed and investigated…”
Get full text
Conference Proceeding