Search Results - "Baghaei, H."
-
1
Modeling the survival of patients with tuberculosis based on the model of artificial neural networks
Published in Health science monitor (01-08-2022)“…Background & Aims: The development of treatment methods and increasing the survival of patients with tuberculosis (TB) has led to the complication of…”
Get full text
Journal Article -
2
Timing Performance Evaluation of PMT-Quadrant-Sharing LYSO Detectors for Time-of-Flight PET
Published in IEEE transactions on nuclear science (01-10-2011)“…Time-of-flight (TOF) data can improve the imaging quality of positron emission tomography (PET) cameras by estimating the location of the positron…”
Get full text
Journal Article -
3
The Engineering and Initial Results of a Transformable Low-cost High-Resolution PET Camera
Published in IEEE transactions on nuclear science (01-10-2007)“…We have developed a high-resolution transformable positron emission tomography (PET) camera that can be configured into either a whole-body mode (83-cm…”
Get full text
Journal Article -
4
Monte Carlo Simulation Study on the Time Resolution of a PMT-Quadrant-Sharing LSO Detector Block for Time-of-Flight PET
Published in IEEE transactions on nuclear science (01-10-2009)“…We developed a detailed Monte Carlo simulation method to study the time resolution of detectors for time-of-flight positron emission tomography (TOF PET). The…”
Get full text
Journal Article -
5
A Lower-Cost High-Resolution LYSO Detector Development for Positron Emission Mammography (PEM)
Published in IEEE transactions on nuclear science (01-10-2009)“…In photomultiplier-quadrant-sharing (PQS) geometry for positron emission tomography applications, each PMT is shared by four blocks and each detector block is…”
Get full text
Journal Article -
6
GATE Monte Carlo Simulation of a High-Sensitivity and High-Resolution LSO-Based Small Animal PET Camera
Published in IEEE transactions on nuclear science (01-10-2007)“…In this paper, we describe a Monte Carlo simulation of the performance of a high-sensitivity and high-resolution small animal positron emission tomography…”
Get full text
Journal Article -
7
A pentagon photomultiplier-quadrant-sharing BGO detector for a rodent research PET (RRPET)
Published in IEEE transactions on nuclear science (01-02-2005)“…Using the photomultiplier-quadrant-sharing (PQS) technique, we designed pentagonal detector blocks with high resolution (2.0 mm) and high sensitivity for a…”
Get full text
Journal Article -
8
The design of a high-resolution transformable wholebody PET camera
Published in IEEE transactions on nuclear science (01-10-2002)“…The conceptual design of a high-resolution positron emission tomography (PET) camera is presented. This PET has a transformable transaxial and axial fields of…”
Get full text
Journal Article -
9
Feasibility of a High-Speed Gamma-Camera Design Using the High-Yield-Pileup-Event-Recovery Method
Published in The Journal of nuclear medicine (1978) (01-04-2001)“…Higher count-rate gamma cameras than are currently used are needed if the technology is to fulfill its promise in positron coincidence imaging, radionuclide…”
Get full text
Journal Article -
10
High resolution GSO block detectors using PMT-quadrant-sharing design for small animal PET
Published in IEEE transactions on nuclear science (01-02-2006)“…GSO position-sensitive block detectors have been developed using the PMT-Quadrant -Sharing (PQS) technology for animal PET imaging. Two prototype block…”
Get full text
Journal Article -
11
An instantaneous photomultiplier tube gain-tuning method for PET or gamma camera detectors using an LED network
Published in IEEE transactions on nuclear science (01-10-2005)“…A photomultiplier tube (PMT) gain can change with many environmental factors, such as room temperature, patient load, short-term or long-term radiation…”
Get full text
Journal Article -
12
New 9 \,\times\,9 and 10 \,\times\,10 BGO Block Detector for Human PET Using PMT Quadrant Sharing Design
Published in IEEE transactions on nuclear science (01-02-2008)“…Our objectives were to develop two 9times9 and 10times10 array high resolution position sensitive block detectors using low cost…”
Get full text
Journal Article -
13
A Simulation Study on Optically Decoding Reflecting Windows for PMT Quadrant Sharing Scintillation Detector Block
Published in IEEE transactions on nuclear science (01-10-2006)“…A large number of decodable crystals per photomultiplier tube (PMT) can be achieved by using the PMT-quadrant-sharing (PQS) technique with proper optically…”
Get full text
Journal Article -
14
An efficient detector production method for position-sensitive scintillation detector arrays with 98% detector packing fraction
Published in IEEE transactions on nuclear science (01-10-2003)“…Position-sensitive scintillation-detector arrays (PSSDAs) are used in nuclear-imaging methods such as PET. The kind of technique selected in producing the…”
Get full text
Journal Article -
15
A new pileup-prevention front-end electronic design for high-resolution PET and gamma cameras
Published in IEEE transactions on nuclear science (01-10-2002)“…A new method for processing signals from Anger position-sensitive detectors used in gamma cameras and positron emission tomography (PET) is proposed for very…”
Get full text
Journal Article -
16
Signal characteristics of individual crystals in high resolution BGO detector designs using PMT-quadrant sharing
Published in IEEE transactions on nuclear science (01-06-2003)“…The PMT-quadrant sharing (PQS) detector design allows very high resolution detectors to be built with 70% fewer PMTs and lower cost. A common concern for the…”
Get full text
Journal Article -
17
A simple respiration gating technique and its application in high-resolution PET camera
Published in IEEE transactions on nuclear science (01-02-2005)“…We have developed a simple technique to gate positron emission tomography (PET) imaging in synchronization with respiratory motion to reduce image blurring…”
Get full text
Journal Article -
18
A modular low dead-time coincidence system for high-resolution PET cameras
Published in IEEE transactions on nuclear science (01-10-2003)“…A high-resolution oncologic transformable positron emission tomography (HOTPET) is currently under development. The detector ring of the camera consists of 12…”
Get full text
Journal Article -
19
Gantry design with accurate crystal positioning for a high-resolution transformable PET camera
Published in IEEE transactions on nuclear science (01-02-2005)“…A positron emission tomography (PET) camera capable of transforming its geometric configuration is being developed. This high-resolution oncologic…”
Get full text
Journal Article -
20
Evaluation of the effect of filter apodization for volume PET imaging using the 3-D RP algorithm
Published in IEEE transactions on nuclear science (01-02-2003)“…We investigated the influence of filter apodization and cutoff frequency on the image quality of volume positron emission tomography (PET) imaging using the…”
Get full text
Journal Article