Comparative study of descendent colon rupture resistance considering traction force of rupture and total energy of rupture in rats

To compare total energy of rupture and traction force of rupture tests within a rupture resistance study of descendent colon of rats. Twelve descendent colon segments of rats were considered to perform the study. For each one of the specimens, total energy of rupture and traction force of rupture ne...

Full description

Saved in:
Bibliographic Details
Published in:Acta cirúrgica brasileira Vol. 21; no. 2; pp. 97 - 100
Main Authors: Wu, Feng Chung, Lee, Huei Diana, Niz, Maksoel Algustin Krauspenhar, Ayrizono, Maria de Loudes Setsuko, Coy, Cláudio Saddy Rodrigues, Góes, Juvenal Ricardo Navarro, Fagundes, João José
Format: Journal Article
Language:English
Published: Brazil Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia 01-04-2006
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To compare total energy of rupture and traction force of rupture tests within a rupture resistance study of descendent colon of rats. Twelve descendent colon segments of rats were considered to perform the study. For each one of the specimens, total energy of rupture and traction force of rupture necessary to promote colic wall burst were evaluated through the biomechanical total energy of rupture test using the Biomechanical Data Acquisition and Analysis System, version 2.0. Average, standard deviation, standard error of average and coefficient of variation were considered for analysis of results. Traction force of rupture average, standard deviation, standard error of average and coefficient of variation were 380.05 gf, 98.74, 28.5 e 25.98%, respectively while total energy of rupture presented average of 244.85 gf, standard deviation of 57.76, standard error of average of 16.67 and coefficient of variation of 23.59. Although, total energy of rupture considered a larger number of attributes to its calculation related to non-linear viscoelastic materials, such as colic wall, it presented a smaller coefficient of variation when compared to traction force of rupture, thus demonstrating to constitute a possible parameter to analyze intestinal resistance of rats.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0102-8650
0102-8650
DOI:10.1590/S0102-86502006000200008