Search Results - "Auvray, Vincent"

Refine Results
  1. 1

    Joint Motion Estimation and Layer Segmentation in Transparent Image Sequences—Application to Noise Reduction in X-Ray Image Sequences by Auvray, Vincent, Bouthemy, Patrick, Liénard, Jean

    “…This paper is concerned with the estimation of the motions and the segmentation of the spatial supports of the different layers involved in transparent X-ray…”
    Get full text
    Journal Article
  2. 2
  3. 3

    Fast kidney detection and segmentation with learned kernel convolution and model deformation in 3D ultrasound images by Ardon, Roberto, Cuingnet, Remi, Bacchuwar, Ketan, Auvray, Vincent

    “…We present a method to segment kidneys in 3D ultrasound images. The main challenges are the high variability in kidney appearance, the frequent presence of…”
    Get full text
    Conference Proceeding
  4. 4

    Contrast enhancement of data measured with area detectors: a way to generalize the use of neutron diffraction for thin-film studies by Bataille, Alexandre M., Auvray, Vincent, Gatel, Christophe, Gukasov, Arsen

    Published in Journal of applied crystallography (01-06-2013)
    “…A denoising method is reported for the treatment of neutron scattering data obtained with position‐sensitive detectors, which enhances the information obtained…”
    Get full text
    Journal Article
  5. 5

    Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization by Mory, Cyril, Auvray, Vincent, Zhang, Bo, Grass, Michael, Schäfer, Dirk, Chen, S. James, Carroll, John D., Rit, Simon, Peyrin, Françoise, Douek, Philippe, Boussel, Loïc

    Published in Medical physics (Lancaster) (01-02-2014)
    “…Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance,…”
    Get full text
    Journal Article
  6. 6

    Joint Motion Estimation and Layer Segmentation in Transparent Image Sequences--Application to Noise Reduction in X-Ray Image Sequences by Auvray, Vincent, Bouthemy, Patrick, Liénard, Jean

    “…This paper is concerned with the estimation of the motions and the segmentation of the spatial supports of the different layers involved in transparent X-ray…”
    Get full text
    Journal Article
  7. 7
  8. 8

    Removing streak artifacts from ECG-gated reconstructions using deconvolution by Mory, Cyril, Auvray, Vincent, Zhang, Bo, Grass, Michael, Schäfer, Dirk, Rit, Simon, Peyrin, Françoise, Douek, Philippe, Boussel, Loïc

    “…4D cardiac computed tomography aims at reconstructing the beating heart from a series of 2D projections and the simultaneously acquired electrocardiogram. Each…”
    Get more information
    Journal Article
  9. 9

    Multi-User MultiWOZ: Task-Oriented Dialogues among Multiple Users by Jo, Yohan, Zhao, Xinyan, Biswas, Arijit, Basiou, Nikoletta, Auvray, Vincent, Malandrakis, Nikolaos, Metallinou, Angeliki, Potamianos, Alexandros

    Published 31-10-2023
    “…While most task-oriented dialogues assume conversations between the agent and one user at a time, dialogue systems are increasingly expected to communicate…”
    Get full text
    Journal Article
  10. 10

    Model-based segmentation of the left main coronary bifurcation from 2D angiograms by Lacroix, R., Florent, R., Auvray, V.

    “…This paper deals with the identification of the left main coronary bifurcation (LMB) in 2D angiograms. We resort to a generic 3D model of the LMB that is…”
    Get full text
    Conference Proceeding
  11. 11

    OodGAN: Generative Adversarial Network for Out-of-Domain Data Generation by Marek, Petr, Naik, Vishal Ishwar, Auvray, Vincent, Goyal, Anuj

    Published 06-04-2021
    “…Detecting an Out-of-Domain (OOD) utterance is crucial for a robust dialog system. Most dialog systems are trained on a pool of annotated OOD data to achieve…”
    Get full text
    Journal Article
  12. 12

    Geometry-constrained coronary arteries motion estimation from 2D angiograms - Application to injection side recognition by Lebois, A, Florent, R, Auvray, V

    “…This paper deals with the 2D motion estimation of coronary arteries. It exploits the geometry of acquisition to strongly constrain the problem, thereby…”
    Get full text
    Conference Proceeding
  13. 13

    Deconvolution for limited-view streak artifacts removal: improvements upon an existing approach by Mory, Cyril, Auvray, Vincent, Bo Zhang, Grass, Michael, Schafer, Dirk, Peyrin, Francoise, Rit, Simon, Douek, Philippe, Boussel, Loic

    “…Cardiac C-Arm computed tomography leads to a view-starved reconstruction problem because of electrocardiogram gating. Reconstruction with the Feldkamp, Davis…”
    Get full text
    Conference Proceeding
  14. 14

    On the Construction of the Inclusion Boundary Neighbourhood for Markov Equivalence Classes of Bayesian Network Structures by Auvray, Vincent, Wehenkel, Louis

    Published 12-12-2012
    “…The problem of learning Markov equivalence classes of Bayesian network structures may be solved by searching for the maximum of a scoring metric in a space of…”
    Get full text
    Journal Article
  15. 15

    Learning Inclusion-Optimal Chordal Graphs by Auvray, Vincent, Wehenkel, Louis

    Published 13-06-2012
    “…Chordal graphs can be used to encode dependency models that are representable by both directed acyclic and undirected graphs. This paper discusses a very…”
    Get full text
    Journal Article
  16. 16
  17. 17

    Dialog Simulation with Realistic Variations for Training Goal-Oriented Conversational Systems by Lin, Chien-Wei, Auvray, Vincent, Elkind, Daniel, Biswas, Arijit, Fazel-Zarandi, Maryam, Belgamwar, Nehal, Chandra, Shubhra, Zhao, Matt, Metallinou, Angeliki, Chung, Tagyoung, Zhu, Charlie Shucheng, Adhikari, Suranjit, Hakkani-Tur, Dilek

    Published 16-11-2020
    “…Goal-oriented dialog systems enable users to complete specific goals like requesting information about a movie or booking a ticket. Typically the dialog system…”
    Get full text
    Journal Article
  18. 18
  19. 19

    ECG-gated C-arm computed tomography using L1 regularization by Mory, C., Zhang, B., Auvray, V., Grass, M., Schafer, D., Peyrin, F., Rit, S., Douek, P., Boussel, L.

    “…Cardiac C-Arm computed tomography leads to a view-starved reconstruction problem because of electrocardiogram gating. The lack of data has to be compensated by…”
    Get full text
    Conference Proceeding
  20. 20