Search Results - "Ask, P"
-
1
The effect of genetic defects on pregnancy loss in Swedish dairy cattle
Published in Journal of dairy science (01-05-2024)“…The effect of carrier status of 10 lethal recessive genetic defects on pregnancy maintenance in Swedish dairy cattle was examined. The genetic defects were…”
Get full text
Journal Article -
2
Genetic parameters of pregnancy loss in dairy cows estimated from pregnancy-associated glycoproteins in milk
Published in Journal of dairy science (01-09-2023)“…This study examined the feasibility of using pregnancy-associated glycoproteins (PAG) in milk within breeding for pregnancy maintenance and assessed the…”
Get full text
Journal Article -
3
Assessment of aortic valve stenosis severity using intelligent phonocardiography
Published in International journal of cardiology (01-11-2015)Get full text
Journal Article -
4
Heart sound cancellation from lung sound recordings using recurrence time statistics and nonlinear prediction
Published in IEEE signal processing letters (01-12-2005)“…Heart sounds (HS) obscure the interpretation of lung sounds (LS). This letter presents a new method to detect and remove this undesired disturbance. The HS…”
Get full text
Journal Article -
5
A method for accurate localization of the first heart sound and possible applications
Published in Physiological measurement (01-03-2008)“…We have previously developed a method for localization of the first heart sound (S1) using wavelet denoising and ECG-gated peak-picking. In this study, an…”
Get more information
Journal Article -
6
Pulse wave transit time for monitoring respiration rate
Published in Medical & biological engineering & computing (01-06-2006)“…In this study, we investigate the beat-to-beat respiratory fluctuations in pulse wave transit time (PTT) and its subcomponents, the cardiac pre-ejection period…”
Get full text
Journal Article -
7
Assessing Aortic Stenosis Using Sample Entropy of the Phonocardiographic Signal in Dogs
Published in IEEE transactions on biomedical engineering (01-08-2008)“…In aortic valve stenosis (AS), heart murmurs arise as an effect of turbulent blood flow distal to the obstructed valves. With increasing AS severity, the flow…”
Get full text
Journal Article -
8
Genetic parameters for reproductive losses estimated from in-line milk progesterone profiles in Swedish dairy cattle
Published in Journal of dairy science (01-03-2021)“…This study assessed the extent of reproductive losses and associated genetic parameters in dairy cattle, using in-line milk progesterone records for 14 Swedish…”
Get more information
Journal Article -
9
Effects of ultrasound contrast agents on Doppler tissue velocity estimation
Published in Journal of the American Society of Echocardiography (2006)“…The combination of Doppler tissue imaging and myocardial contrast echocardiography has the potential to provide information about motion and perfusion of the…”
Get more information
Journal Article -
10
Detection of the third heart sound using a tailored wavelet approach: method verification
Published in Medical & biological engineering & computing (01-03-2005)“…Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with…”
Get full text
Journal Article -
11
Detection of the third heart sound using a tailored wavelet approach
Published in Medical & biological engineering & computing (01-03-2004)“…The third heart sound is normally heard during auscultation of younger individuals but disappears with increasing age. However, this sound can appear in…”
Get full text
Journal Article -
12
Heat transfer evaluation of the nasal thermistor technique
Published in IEEE transactions on biomedical engineering (01-12-1996)“…When analyzing transvalvular and venous flow velocity patterns, it is important to relate them to respiration. An accurate recording of the respiratory phase…”
Get full text
Journal Article -
13
An improved bioacoustic method for monitoring of respiration
Published in Technology and health care (2004)“…Reliable monitoring of respiration plays an important role in a broad spectrum of applications. Today, there are several methods for monitoring respiration,…”
Get more information
Journal Article -
14
A pattern recognition framework for detecting dynamic changes on cyclic time series
Published in Pattern recognition (01-03-2015)“…This paper proposes a framework for binary classification of the time series with cyclic characteristics. The framework presents an iterative algorithm for…”
Get full text
Journal Article -
15
Mathematical model that characterizes transmitral and pulmonary venous flow velocity patterns
Published in The American journal of physiology (01-01-1995)“…The transmitral and pulmonary venous flow velocity (TMFV and PVFV, respectively) patterns are related to the physiological state of the left heart by use of an…”
Get full text
Journal Article -
16
Force to restore the shape of an asymmetric extracorporeal tube as the basis for non-invasive pressure measurements
Published in International journal of artificial organs (01-04-2002)“…A zero-balance principle is described where intraluminal pressure is estimated from the counter force needed to restore the tube shape of an elastic extra…”
Get full text
Journal Article -
17
Bio-acoustic signals from stenotic tube flow : state of the art and perspectives for future methodological development
Published in Medical & biological engineering & computing (01-09-1995)“…To study the degree of stenosis from the acoustic signal generated by the turbulent flow in a stenotic vessel, so-called phonoangiography was first suggested…”
Get full text
Journal Article -
18
Whole-Lake Estimates of Carbon Flux through Algae and Bacteria in Benthic and Pelagic Habitats of Clear-Water Lakes
Published in Ecology (Durham) (01-07-2009)“…This study quantified new biomass production of algae and bacteria in both benthic and pelagic habitats of clear-water lakes to contrast how carbon from the…”
Get full text
Journal Article -
19
An asymmetric dialysis tube as an integrated part of a pressure-monitoring sensor
Published in Technology and health care (2001)“…A sensor has been designed consisting of a tube holder with a force transducer and a tube with a modified cross-section. The holder has a lid that encloses the…”
Get more information
Journal Article -
20
Pediatric cardiac output measurement using surface integration of velocity vectors : An in vivo validation study
Published in Critical care medicine (01-11-2000)“…To test the accuracy and reproducibility of systemic cardiac output (CO) measurements using surface integration of velocity vectors (SIVV) in a pediatric…”
Get full text
Journal Article