  1. 1

    Robust Frequency-Shifting Based Control Amid False Data Injection Attacks for Interconnected Power Systems With Communication Delay by Kumar, Nikhil, Aryan, Pulakraj, Raja, G. Lloyds, Muduli, Utkal Ranjan

    Published in IEEE transactions on industry applications (01-03-2024)
    “…Communication delays and false data injection attacks pose significant threats to the frequency control of automatic generation systems. This article presents…”
    Get full text
    Journal Article
  2. 2

    Tri-parametric Fractional-order Controller Design for Integrating Systems with Time Delay by Mehta, Utkal, Aryan, Pulakraj, Raja, G. Lloyds

    “…This work introduces a new fractional-order integral derivative (FOIλD1-λ) controller for a class of integrating systems involving time delays. The stability…”
    Get full text
    Journal Article
  3. 3

    Decoupled double‐loop FOIMC‐PD control architecture for double integral with dead time processes by Kumar, Deepak, Aryan, Pulakraj, Raja, G. Lloyds

    Published in Canadian journal of chemical engineering (01-12-2022)
    “…A novel double‐loop control configuration with two controllers is suggested for double integrating processes with dead‐time. The stabilizing range of the…”
    Get full text
    Journal Article
  4. 4

    Design and Analysis of Novel QOEO Optimized Parallel Fuzzy FOPI-PIDN Controller for Restructured AGC with HVDC and PEV by Aryan, Pulakraj, Raja, G. Lloyds

    “…Effective controller configuration is an important requirement for the automatic generation and control mechanism as it mitigates noise and improves the…”
    Get full text
    Journal Article
  5. 5

    Experimentally verified optimal bi-loop re-located IMC strategy for unstable and integrating systems with dead time by Aryan, Pulakraj, Raja, G. Lloyds, Vilanova, Ramon

    Published in International journal of systems science (19-05-2023)
    “…Internal model controllers (IMCs) are popular strategies for controlling stable systems with dead time. The relocated IMC (RIMC) design reportedly achieves the…”
    Get full text
    Journal Article
  6. 6

    Equilibrium optimiser tuned frequency-shifted internal model control proportional-derivative decoupled dual-loop design for industrial plants followed by experimental validation by Aryan, Pulakraj, Raja, G. Lloyds, Vilanova, Ramon

    Published in International journal of systems science (25-10-2024)
    “…Integrating and unstable processes require rugged control demand by virtue of their non-self-regulation character. The occurrence of system poles located at…”
    Get full text
    Journal Article
  7. 7

    Dual degree branched type-2 fuzzy controller optimized with a hybrid algorithm for frequency regulation in a triple-area power system integrated with renewable sources by Kumari, Nisha, Aryan, Pulakraj, Raja, G. Lloyds, Arya, Yogendra

    “…The uncertainties associated with multi-area power systems comprising both thermal and distributed renewable generation (DRG) sources such as solar and wind…”
    Get full text
    Journal Article
  8. 8

    Optimal internal model control-based decoupled dual-loop control method for boiler steam drum by Aryan, Pulakraj, Raja, G. Lloyds, Vilanova, Ramon, Meneses, Montse

    “…The decoupled control strategy is a well-established methodology in process control applications. This work-inprogress (WIP) manuscript introduces the…”
    Get full text
    Conference Proceeding
  9. 9

    Repositioned Internal Model Control Strategy on Time-Delayed Industrial Processes With Inverse Behavior Using Equilibrium Optimizer by Aryan, Pulakraj, Lloyds Raja, G., Vilanova, Ramon, Meneses, Montse

    Published in IEEE access (2023)
    “…This paper investigates a repositioned inner-loop stabilized internal model control technique for demanding inverse response industrial processes and…”
    Get full text
    Journal Article
  10. 10

    FOIλD1-λ controller: An alternative to double-loop control schemes for integrating processes by Aryan, Pulakraj, Raja, G. Lloyds, Mehta, Utkal

    “…In this work, a tri-parametric non-integer controller is suggested as an alternative for double loop control schemes for controlling dynamics of higher order…”
    Get full text
    Conference Proceeding
  11. 11

    Optimal RIMC-based DLC strategy for time-delayed higher-order integrating and unstable processes with a case study on inverted pendulum by Aryan, Pulakraj, Raja, G. Lloyds, Muduli, Utkal Ranjan

    “…This study explores a double loop control (DLC) mechanism enhanced by a relocated internal model control (RIMC) approach, tailored for complex industrial…”
    Get full text
    Conference Proceeding
  12. 12

    Design of a novel fractional‐order internal model controller‐based Smith predictor for integrating processes with large dead‐time by Kumar, Deepak, Aryan, Pulakraj, Raja, G. Lloyds

    “…A novel multi‐loop control configuration with two controllers is suggested for integrating processes having large dead‐time. The inner‐loop consists of a Smith…”
    Get full text
    Journal Article
  13. 13

    Type-2 fuzzy-based branched controller tuned using arithmetic optimizer for load frequency control by Anand, Abhishek, Aryan, Pulakraj, Kumari, Nisha, Raja, G. Lloyds

    “…Frequency deviations are triggered by load changes and the inclusion of renewable energy sources. Hence, a novel type-2 fuzzy proportional derivative-integral…”
    Get full text
    Journal Article
  14. 14

    Analysis of Type-2 Fuzzy IλDμ-P Controller for LFC with Communication Delay by Aryan, Pulakraj, Raja, G. Lloyds

    “…Uncertainties associated with the modern power system (PS) due to fluctuating load demand as well as the intermittent nature of renewable sources require…”
    Get full text
    Conference Proceeding
  15. 15

    Robust Stability and Sensitivity Analysis of Optimized Fuzzy Integral-Derivative Controllers in Multi-Area Hybrid Power Systems by Kumari, Nisha, Aryan, Pulakraj, Raja, G. Lloyds, Muduli, Utkal Ranjan

    “…This study introduces a new type-two fuzzy-aided integral-derivative looped with a proportional-derivative FAI D - (P D) l controller for achieving secondary…”
    Get full text
    Conference Proceeding
  16. 16

    Application of Quasi Opposition Based Whale Algorithm for LFC of Multi-area Deregulated Power System Using Fractional Controller by Vidyarthi, Prabhat Kumar, Kumar, Ashiwani, Aryan, Pulakraj

    “…In this paper, novel Quasi Opposition based Whale Algorithm (QOWOA) is proposed for Automatic generation control (AGC) for two area interconnected power system…”
    Get full text
    Conference Proceeding
  17. 17

    EO Optimized Novel Type-2 Fuzzy ID-P Controller for LFC of Deregulated Multi-area Power System with Robust Stability Analysis by Anand, Abhishek, Kumari, Nisha, Aryan, Pulakraj, Raja, G. Lloyds

    “…Due to the availability of an extra dimension in the membership functions, type-2 fuzzy logic controllers are more efficient in handling uncertainties and…”
    Get full text
    Conference Proceeding
  18. 18

    A Novel Optimization Technique for LFC and Virtual Inertia Emulation of a Multi Area Hybrid Power System by Murali, Sariki, Shankar, Ravi, Aryan, Pulakraj

    “…Frequency regulation is one of the important power quality issues of an interconnected power system. Load Frequency Control (LFC) is a classic approach for…”
    Get full text