Search Results - "Amorós, Gerard"

  • Showing 1 - 18 results of 18
Refine Results
  1. 1
  2. 2
  3. 3

    Summation and Cancellation Effects on QRS and ST-Segment Changes Induced by Simultaneous Regional Myocardial Ischemia by Vives-Borrás, Miquel, Jorge, Esther, Amorós-Figueras, Gerard, Millán, Xavier, Arzamendi, Dabit, Cinca, Juan

    Published in Frontiers in physiology (03-04-2018)
    “…Simultaneous ischemia in two myocardial regions is a potentially lethal clinical condition often unrecognized whose corresponding electrocardiographic (ECG)…”
    Get full text
    Journal Article
  4. 4

    Recognition of Fibrotic Infarct Density by the Pattern of Local Systolic-Diastolic Myocardial Electrical Impedance by Amorós-Figueras, Gerard, Jorge, Esther, García-Sánchez, Tomás, Bragós, Ramón, Rosell-Ferrer, Javier, Cinca, Juan

    Published in Frontiers in physiology (31-08-2016)
    “…Myocardial electrical impedance is a biophysical property of the heart that is influenced by the intrinsic structural characteristics of the tissue. Therefore,…”
    Get full text
    Journal Article Publication
  5. 5

    Changes in Local Atrial Electrograms and Surface ECG Induced by Acute Atrial Myocardial Infarction by Amorós-Figueras, Gerard, Roselló-Diez, Elena, Sanchez-Quintana, Damian, Casabella-Ramon, Sergi, Jorge, Esther, Nevado-Medina, Jorge, Arzamendi, Dabit, Millán, Xavier, Alonso-Martin, Concepción, Guerra, Jose M, Cinca, Juan

    Published in Frontiers in physiology (17-04-2020)
    “…Atrial coronary branch occlusion is a hardly recognizable clinical entity that can promote atrial fibrillation. The low diagnostic accuracy of the ECG could…”
    Get full text
    Journal Article
  6. 6

    Influence of Left Bundle Branch Block on the Electrocardiographic Changes Induced by Acute Coronary Artery Occlusion of Distinct Location and Duration by Jorge, Esther, Solé-González, Eduard, Amorós-Figueras, Gerard, Arzamendi, Dabit, Guerra, Jose M, Millán, Xavier, Vives-Borrás, Miquel, Cinca, Juan

    Published in Frontiers in physiology (12-02-2019)
    “…Electrocardiographic (ECG) diagnosis of acute myocardial ischemia is hampered in the presence of left bundle branch block (LBBB). We analyzed the influence of…”
    Get full text
    Journal Article
  7. 7

    Dynamics of High-Density Unipolar Epicardial Electrograms During PFA by Amorós-Figueras, Gerard, Casabella-Ramon, Sergi, Moreno-Weidmann, Zoraida, Ivorra, Antoni, Guerra, Jose M, García-Sánchez, Tomás

    “…Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable…”
    Get full text
    Journal Article
  8. 8

    Parametric Study of Pulsed Field Ablation With Biphasic Waveforms in an In Vivo Heart Model: The Role of Frequency by García-Sánchez, Tomás, Amorós-Figueras, Gerard, Jorge, Esther, Campos, María C., Maor, Elad, Guerra, Jose M., Ivorra, Antoni

    “…Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the…”
    Get full text
    Journal Article
  9. 9

    Endocardial infarct scar recognition by myocardial electrical impedance is not influenced by changes in cardiac activation sequence by Amorós-Figueras, Gerard, Jorge, Esther, Alonso-Martin, Concepción, Traver, Daniel, Ballesta, Maria, Bragós, Ramon, Rosell-Ferrer, Javier, Cinca, Juan

    Published in Heart rhythm (01-04-2018)
    “…Measurement of myocardial electrical impedance can allow recognition of infarct scar and is theoretically not influenced by changes in cardiac activation…”
    Get full text
    Journal Article Publication
  10. 10
  11. 11

    Early detection of acute transmural myocardial ischemia by the phasic systolic-diastolic changes of local tissue electrical impedance by Jorge, Esther, Amorós-Figueras, Gerard, García-Sánchez, Tomás, Bragós, Ramón, Rosell-Ferrer, Javier, Cinca, Juan

    “…Myocardial electrical impedance is influenced by the mechanical activity of the heart. Therefore, the ischemia-induced mechanical dysfunction may cause…”
    Get more information
    Journal Article
  12. 12

    ST-segment deviation behavior during acute myocardial ischemia in opposite ventricular regions: Observations in the intact and perfused heart by Cinca, Juan, MD, PhD, Noriega, Francisco Javier, MD, Jorge, Esther, DVM, PhD, Alvarez-Garcia, Jesús, MD, Amoros, Gerard, MSc, Arzamendi, Dabit, MD

    Published in Heart rhythm (01-11-2014)
    “…Background Acute myocardial ischemia in opposite regions may attenuate ST-segment changes, but whether this effect is expressed differently in extracardiac…”
    Get full text
    Journal Article
  13. 13
  14. 14

    Comparison between endocardial and epicardial cardiac resynchronization in an experimental model of non-ischaemic cardiomyopathy by Amorós-Figueras, Gerard, Jorge, Esther, Raga, Silvia, Alonso-Martin, Concepcion, Rodríguez-Font, Enrique, Bazan, Victor, Viñolas, Xavier, Cinca, Juan, Guerra, Jose M

    Published in Europace (London, England) (01-07-2018)
    “…Pacing from the left ventricular (LV) endocardium might increase the likelihood of response to cardiac resynchronization therapy. However, experimental and…”
    Get full text
    Journal Article
  15. 15
  16. 16

    Myocardial contractility assessed by dynamic electrical impedance measurements during dobutamine stress by Garcia-Sanchez, Tomas, Jorge, Esther, Amoros-Figueras, Gerard, Bragos, Ramon, Cinca, Joan, Rosell-Ferrer, Javier

    “…In this study, the electrical impedance of myocardial tissue is measured dynamically during the cardial cycle. The multisine-based approach used to perform…”
    Get full text
    Conference Proceeding Journal Article Publication
  17. 17
  18. 18

    High- T c superconducting quantum interference device recordings of spontaneous brain activity: Towards high- T c magnetoencephalography by Öisjöen, F., Schneiderman, J. F., Figueras, G. A., Chukharkin, M. L., Kalabukhov, A., Hedström, A., Elam, M., Winkler, D.

    Published in Applied physics letters (26-03-2012)
    “…We have performed single- and two-channel high transition temperature (high- T c ) superconducting quantum interference device (SQUID) magnetoencephalography…”
    Get full text
    Journal Article