Search Results - "Almeida, Adelaide De"
-
1
Prevention of transfusion-associated graft-versus-host disease by irradiation: technical aspect of a new ferrous sulphate dosimetric system
Published in PloS one (07-06-2013)“…Irradiation of whole blood and blood components before transfusion is currently the only accepted method to prevent Transfusion-Associated…”
Get full text
Journal Article -
2
Dosimetric parameters for small field sizes using Fricke xylenol gel, thermoluminescent and film dosimeters, and an ionization chamber
Published in Physics in medicine & biology (07-03-2007)“…Dosimetric measurements in small therapeutic x-ray beam field sizes, such as those used in radiosurgery, that have dimensions comparable to or smaller than the…”
Get more information
Journal Article -
3
Surface damage studies of ETFE polymer bombarded with low energy Si ions (⩽100keV)
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-08-2007)“…Surface studies of ethylenetetrafluoroethylene (ETFE), bombarded with Si in a high-energy tandem Pelletron accelerator, have recently been reported. Si ion…”
Get full text
Journal Article -
4
Mycosis Fungoides electron beam absorbed dose distribution using Fricke xylenol gel dosimetry
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (15-12-2011)“…Radiotherapy uses ionizing radiation to destroy tumor cells. The absorbed dose control in the target volume is realized through radiation sensors, such as…”
Get full text
Journal Article -
5
Gap application results for adjacent electron beams treatment
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (15-12-2011)“…Nowadays, electron beams from high-energy linear accelerators (LINAC) are widely used in a variety of radiotherapy treatments being suitable especially for…”
Get full text
Journal Article -
6
Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry
Published in Physics in medicine & biology (21-03-2005)“…Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement…”
Get more information
Journal Article -
7
Relative output factor and beam profile measurements of small radiation fields with an L-alanine/K-Band EPR minidosimeter
Published in Medical physics (Lancaster) (01-05-2007)“…The performance of an L-alanine dosimeter with millimeter dimensions was evaluated for dosimetry in small radiation fields. Relative output factor (ROF)…”
Get full text
Journal Article -
8
Mammography grid performance
Published in Radiology (01-01-1999)“…To measure directly the grid performance of mammography units for the range of breast thicknesses and x-ray tube potentials encountered in clinical practice…”
Get more information
Journal Article -
9
Fricke Xylenol Gel characterization at megavoltage radiation energy
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-03-2017)“…Accurate determination of absorbed dose is of great importance in every medical application of ionizing radiation, mainly when involving biological tissues…”
Get full text
Journal Article -
10
Fricke gel diffusion coefficient measurements for applications in radiotherapy level dosimetry
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-05-2014)“…In gel dosimetry applied to radiotherapy, the space–time corrections are necessary due to the diffusion of ions in the oxidized solution dosimetry…”
Get full text
Journal Article -
11
Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements
Published in Applied radiation and isotopes (01-08-2014)“…In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe3+ in Fricke…”
Get full text
Journal Article -
12
Measurements of the Fe super(3+) diffusion coefficient in Fricke Xylenol gel using optical density measurements
Published in Applied radiation and isotopes (01-08-2014)“…In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe super(3+) in…”
Get full text
Journal Article -
13
Monte Carlo Simulations for Small Electron Field Size Irradiation
Published in IEEE transactions on nuclear science (01-04-2013)“…Fricke Xylenol Gel (FXG) is a chemical dosimeter based on swine skin gelatin, Xylenol Orange (XO) and ferrous sulphate. When irradiated with ionizing…”
Get full text
Journal Article -
14
Measuring output factors and beam profiles formed by multileaf collimators using Fricke gel dosimeter
Published in Physica medica (01-11-2014)“…Abstract The accuracy and precision are necessary factors in radiotherapy, especially for measurements involving output factors and beam profiles; in this case…”
Get full text
Journal Article -
15
8 and 10 MeV Electron Beams Small Field-Size Dosimetric Parameters Through the Fricke Xylenol Gel Dosimeter
Published in IEEE transactions on nuclear science (01-04-2013)“…When small field sizes are recommended in radiotherapy, the dosimeter must have an adequate spatial resolution in order to determine the absorbed dose at the…”
Get full text
Journal Article -
16
Quality Assurance of a Two-Dimensional CCD Detector System Applied in Dosimetry
Published in IEEE transactions on nuclear science (01-04-2013)“…Nowadays, charge-coupled devices (CCDs) are applied for many technological purposes, including areas as astronomy, medical diagnosis and the ones related to…”
Get full text
Journal Article -
17
Beta planar source quality assurance with the Fricke xylenol gel dosimeter
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-03-2014)“…Beta therapy is employed in post surgery to treat lesions such as pterygia, keloid and glioblastoma. The beta source most used for these purposes is 90/90Y,…”
Get full text
Journal Article -
18
Correction: Prevention of Transfusion-Associated Graft-versus-Host Disease by Irradiation: Technical Aspect of a New Ferrous Sulphate Dosimetric System
Published in PloS one (03-01-2014)Get full text
Journal Article -
19
Fricke dosimeter gel measurements of the profiles of shielded fields
Published in Applied radiation and isotopes (01-12-2013)“…In radiation therapy, the shielding of normal tissue can be made using Cerrobend® blocks or a multileaf collimator. In this work, profiles of shielded fields…”
Get full text
Journal Article -
20
Determination of diffusion coefficient in Fricke Xylenol gel dosimeter after electron beam bombardment
Published in Surface & coatings technology (15-06-2009)“…The Fricke Xylenol Gel (FXG) dosimeter is a ferrous sulfate aqueous solution that, when irradiated or subject to heat, oxygen and light, oxidizes the Fe@u2@u+…”
Get full text
Conference Proceeding Journal Article