Search Results - "ARCIDIACONO, R"
-
1
A new timing detector for the CT-PPS project
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-02-2017)“…The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200m downstream the interaction point. This detector will measure forward…”
Get full text
Journal Article -
2
Radiation resistant LGAD design
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-03-2019)“…In this paper, we report on the radiation resistance of 50-micron thick Low Gain Avalanche Diodes (LGAD) manufactured at the Fondazione Bruno Kessler (FBK)…”
Get full text
Journal Article -
3
First FBK production of 50 μm ultra-fast silicon detectors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-04-2019)“…Fondazione Bruno Kessler (FBK, Trento, Italy) has recently delivered its first 50 μm thick production of Ultra-Fast Silicon Detectors (UFSD), based on the…”
Get full text
Journal Article -
4
Analysis and numerical design of Resistive AC-Coupled Silicon Detectors (RSD) for 4D particle tracking
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-04-2020)“…In this paper we present the numerical simulation of silicon detectors with internal gain as the main tool for 4-dimensional (4D) particle trackers design and…”
Get full text
Journal Article -
5
Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-04-2017)“…In this paper we report on the timing resolution obtained in a beam test with pions of 180 GeV/c momentum at CERN for the first production of 45 μm thick…”
Get full text
Journal Article -
6
A Two-Prong Approach to the Simulation of DC-RSD: TCAD and SPICE
Published in IEEE transactions on nuclear science (01-02-2024)“…The DC-coupled resistive silicon detectors (DC-RSD) are the evolution of the AC-coupled RSD (RSD) design, both based on the low-gain avalanche diode (LGAD)…”
Get full text
Journal Article -
7
Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2021)“…The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low…”
Get full text
Journal Article -
8
Experimental Study of Acceptor Removal in UFSD
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2020)“…The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin…”
Get full text
Journal Article -
9
A new low gain avalanche diode concept: the double-LGAD
Published in European physical journal plus (07-11-2023)“…This paper describes the new concept of the double LGAD (low-gain avalanche diodes). The goal was to increase the charge at the input of the electronics,…”
Get full text
Journal Article -
10
Beam test results of 25 and 35 μm thick FBK ultra-fast silicon detectors
Published in European physical journal plus (30-01-2023)“…This paper presents the measurements on first very thin Ultra-Fast Silicon Detectors (UFSDs) produced by Fondazione Bruno Kessler; the data have been collected…”
Get full text
Journal Article -
11
The Gigatracker, the silicon beam tracker for the NA62 experiment at CERN
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-04-2020)“…The Gigatracker is the NA62 beam tracker. It is made of three 63.1mm×29.3mm stations of 300μm×300μm hybrid silicon pixel detectors installed in vacuum…”
Get full text
Journal Article -
12
The NA62 GigaTracker
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-02-2017)“…The GigaTracker is a hybrid silicon pixel detector built for the NA62 experiment aiming at measuring the branching fraction of the ultra-rare kaon decay…”
Get full text
Journal Article -
13
The Gigatracker detector of the NA62 experiment at CERN SPS
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-08-2019)“…The NA62 experiment at the CERN SPS is a fixed target experiment designed to measure the branching ratio of the ultra-rare Kaon decay K+→π+νν̄. The experiment…”
Get full text
Journal Article -
14
Induced responses of Bougainvillea glabra Choisy (Nyctaginaceae) against Phenacoccus peruvianus Granara de Willink (Hemiptera: Pseudococcidae) attack: preliminary results
Published in Arthropod-plant interactions (01-02-2018)“…Plants respond to herbivorous attack through a defence system that includes structural barriers, release of toxic chemicals, and attraction of natural enemies…”
Get full text
Journal Article -
15
A new timing detector for the CT-PPS project
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (30-05-2016)“…The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200 m downstream the interaction point. This detector will measure forward…”
Get full text
Journal Article -
16
Detection of a novel allergen in raw tomato
Published in Journal of investigational allergology & clinical immunology (2008)“…The study reports a case of "pure" tomato allergy in an adult female. The responsible allergen was partially characterized by immunoblot analysis, pepsin…”
Get full text
Journal Article -
17
Long-term efficacy of endoscopic stenting in patients with stricture of the biliary anastomosis after orthotopic liver transplantation
Published in Endoscopy (01-05-1998)“…The choledocho-choledochostomy (CCS) stricture is one of the most frequent complications occurring after liver transplantation. Endoscopic retrograde…”
Get more information
Journal Article -
18
Innovative DC-resistive read-out in silicon sensors: internal gain and signal sharing for future 4D tracking
Published in 2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD) (04-11-2023)“…Recent developments in sensor design are opening the way to high resolution 4D-tracking detectors, able to measure concurrently position and time of passage of…”
Get full text
Conference Proceeding -
19
4D tracking: present status and perspectives
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-10-2022)“…The past ten years have seen the advent of silicon-based precise timing detectors for charged particle tracking. The underlying reason for this evolution is a…”
Get full text
Journal Article -
20
Demonstration of 200-, 100-, and 50- \mu m Pitch Resistive AC-Coupled Silicon Detectors (RSD) With 100% Fill-Factor for 4D Particle Tracking
Published in IEEE electron device letters (01-11-2019)“…We designed, produced, and tested RSD (Resistive AC-Coupled Silicon Detectors) devices, an evolution of the standard LGAD (Low-Gain Avalanche Diode) technology…”
Get full text
Journal Article