Search Results - "2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC)"
-
1
Timing resolution performance comparison for fast and standard outputs of SensL SiPM
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…A new silicon photomultiplier (SiPM) with a unique fast output signal feature was recently introduced by SensL. For a SiPM device with 3×3 mm 2 sensitive area,…”
Get full text
Conference Proceeding -
2
A realistic digital phantom for perfusion C-arm CT based on MRI data
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…CTP is an important imaging modality for diagnosis of ischemic stroke, which is computed from of a series of consecutive CT-scans during the injection of…”
Get full text
Conference Proceeding -
3
Petiroc, a new front-end ASIC for time of flight application
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Petiroc is a 16-channel front-end ASIC designed to readout silicon photomultipliers (SiPMs) for particle time-of-flight measurement applications. Petiroc…”
Get full text
Conference Proceeding -
4
Image science with photon-processing detectors
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…We introduce and discuss photon-processing detectors and we compare them with photon-counting detectors. By estimating a relatively small number of attributes…”
Get full text
Conference Proceeding -
5
FlexToT - Current mode ASIC for readout of common cathode SiPM arrays
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…A front end application specific integrated circuit (ASIC) for the readout of common cathode Silicon Photo-Multipliers arrays is presented with the following…”
Get full text
Conference Proceeding -
6
A visi-coil fiducial markers detection method on kV projection images during prostate radiation therapy
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Here an accurate automated method based on fast marching approach for detecting visi-coil fiducial markers by using kV imaging is presented. Visi-coil…”
Get full text
Conference Proceeding -
7
Quantitative whole-body parametric PET imaging incorporating a generalized Patlak model
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Recently, we proposed a dynamic multi-bed PET imaging and analysis framework enabling clinically feasible whole-body parametric imaging. The standard Patlak…”
Get full text
Conference Proceeding -
8
Assessment of Microsoft Kinect technology (Kinect for Xbox and Kinect for windows) for patient monitoring during external beam radiotherapy
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…In external beam radiotherapy, patient misalignment during set-up and motion during treatment may result in lost dose to target tissue and increased dose to…”
Get full text
Conference Proceeding -
9
Performance of X-ray detectors with SiPM readout in cargo accelerator-based inspection systems
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Existing requirements for high throughput cargo radiography inspection include high resolution images (better than 5 mm line pair resolution), penetration…”
Get full text
Conference Proceeding -
10
Direct reconstruction of CT-based attenuation correction images for PET with cluster-based penalties
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Extremely low-dose CT acquisitions for the purpose of PET attenuation correction will have a high level of noise and biasing artifacts due to factors such as…”
Get full text
Conference Proceeding -
11
Effects of dark counts on Digital Silicon Photomultipliers performance
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Digital Silicon Photomultipliers (dSiPM) are novel light detector that integrates single-photon avalanche photodiodes and CMOS logic into a single silicon chip…”
Get full text
Conference Proceeding -
12
ePix: A class of front-end ASICs for second generation LCLS integrating hybrid pixel detectors
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…ePix is a novel class of ASICs architectures based on a common platform optimized for the processing of signals in second generation LCLS cameras. The platform…”
Get full text
Conference Proceeding -
13
Hygroscopicity evaluation of halide scintillators
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…A collaborative study of relative hygroscopicity of anhydrous halide scintillators grown at various laboratories is presented. We have developed a technique to…”
Get full text
Conference Proceeding -
14
Comparison of different methods for data-driven respiratory gating of PET data
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Respiratory movement degrades image quality in PET/CT. The first step in correcting for movement is to gate the data into different motion states. In current…”
Get full text
Conference Proceeding -
15
Design studies of a CZT-based detector combined with a pixel-geometry-matching collimator for SPECT imaging
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Single Photon Emission Computed Tomography (SPECT) suffers limited efficiency due to the need for collimators. Collimator properties largely decide the data…”
Get full text
Conference Proceeding -
16
Rapid rabbit: Highly optimized GPU accelerated cone-beam CT reconstruction
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Graphical processing units (GPUs) have become widely adopted in the medical imaging community. The parallel SIMD nature of GPUs maps perfectly to many…”
Get full text
Conference Proceeding -
17
A method for simultaneous image reconstruction and beam hardening correction
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Beam hardening is a well known effect in CT scanners that is cause by a combination of a broad polychromatic source X-ray spectrum and energy-dependent…”
Get full text
Conference Proceeding -
18
Radiation hardness and detector performance of new 180nm CMOS MAPS prototype test structures developed for the upgrade of the ALICE Inner Tracking System
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…The features of the 180nm TowerJazz 1 CMOS technology allow for the first time the use of CMOS Monolithic Active Pixel Sensors (MAPS) under the harsh…”
Get full text
Conference Proceeding -
19
A PET detector module using FPGA-only MVT digitizers
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Multi-voltage threshold (MVT) is an amplitude-based sampling method. It takes timing samples when the event pulse crosses the user-defined thresholds. Only a…”
Get full text
Conference Proceeding -
20
Experimental evaluation of a deformable registration algorithm for motion correction in PET-CT guided biopsy
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…Positron emission tomography computed tomography (PET-CT) images are increasingly being used for guidance during percutaneous biopsy. However, due to the…”
Get full text
Conference Proceeding